Adjusting the gas pressure in a navyen boiler

The setting

Navien is programmed for winter (heating and DHW) and summer (DHW) modes of operation. with icons Snowflake and Sunny. Adjustment of the mains temperature on the LCD panel is performed when the radiator icon is lit. In some versions, start Heating Mode, in others, scroll the knob. The flashing LED indicates the set temperature of the water.

If the icon is simply lit without pulsating, the actual mains temperature is displayed. After selecting the icon, in or.,Increase or decrease the temperature. After a few seconds the LED stops blinking and shows the real temperature. Regulate the temperature of the heating from 40.0 C to 80.0 С. If it is not set correctly an error code will be displayed.

Note! The DHW temperature is adjusted in the same way, only on the remote control icon with a tap, the range is from 30 to 60 C.

Operation modes

Like many heating devices, boilers Navien have a winter and summer modes of operation. On the display, the button to change modes is indicated by the icon “Snowflake” and “Sunshine”.

By pressing this button repeatedly, you can change the options:

You can adjust the temperature of the coolant on the remote control when the display lights up the icon with the heater.

In some models to do this you need to press the “Heating mode” button, in others you need to turn the knob with this icon.

The flashing icon of the radiator means that the numbers you see show the set t of the coolant.

If the “radiator” just lights up. the actual temperature in the heating is displayed.

After selecting “radiator”, you must press the “” or “-” keys to increase or decrease the temperature. A few seconds after the desired temperature is set, the radiator icon stops flashing, and the display will show data on what t of the coolant now, and the device will begin to gradually heat it (or cool it down) to the selected.

Gas pressure Navien boiler

Instructions for setting the gas pressure on gas boilers Navien (Navien)

Raise or lower the gas pressure in boilers Navien Ace, Deluxe, Atmo, Prime you can help pressure gauge with a scale of mm/H2O digital differential.

Tables with gas pressure values for different Navien boilers can be found at the end of this manual.

Navien Training

Switch off NAVIEN boiler from the power supply2. Connect the manometer to the gas pressure test connection on the burner Manometer connection diagram for adjusting the gas pressure of the Navien 3 boiler. Switch on the boiler. 5) Set the DIP switch on the control unit of the boiler to the down position, to set the minimum load. 4. Close the water supply taps. Set the minimum gas pressure according to the table on the adjustment screw on the gas valve (Increase pressure. turn counter-clockwise, decrease pressure. turn screw clockwise) 5. Switching off the power supply. Set the DIP switch on the control unit to UP (basic setting)6. Set DIP switch on control unit to DOWN, to set max load. 7. Switch on the power. Set the maximum gas pressure according to the table with the adjusting screw on the boiler control board (Increase. turn counterclockwise, decrease. turn clockwise) 8. Switch off the boiler and disconnect the pressure gauge hose from the gas valve connector9. Set DIP switch on the control board to UP (Basic setting)10. Switch on the boiler and check the tightness of gas valve (connection). If unusual noises appear, it is necessary to check the boiler for gas leakage.Spare parts for boilers NavienGas boilers NavienElectric boilers NavienDiesel boilers Navien table gas pressure Navien Ace boilers table gas pressure Navien Ace Coaxial boilers table gas pressure Navien Ace Atmo boilers table gas pressure Navien Deluxe boilers table gas pressure Navien Deluxe Coaxial boilers table gas pressure Navien Prime

Setting

“Navien is programmed for winter mode (heating and domestic hot water) and summer mode (hot water). with the icons “Snowflake” and “Sun”. The mains temperature is adjusted on the LCD remote control when the “radiator” icon is illuminated. In some variants start “Heating mode”, in others the knob is cranked. Blinking LED indicates the set temperature of water.

If the icon is simply lit without pulsation. the actual temperature in the network is displayed. By selecting the icon, through “” or “-“, increase or decrease the temperature. After a couple of seconds the LED will stop flashing and show the real temperature. Regulate the heating temperature from 40.0 C to 80.0 С. If it is not installed correctly error code will appear.

Please note! Regulation of DHW temperature is carried out in the same way, only on the icon with a tap, the range is from 30 to 60 C.

Answers : Gas boiler NAVIEN ACE

Make up system as organized? From the water mains through the non-return valve?

I would like to know if the heating system is new or old? No need to add pressure to the expansion tank. The tank contains nitrogen, not air, and the pressure is set to 1 atm from the factory. The system may have a leak that is difficult to detect. A slowly dripping drop has time to dry out on a pipe or radiator, but the pressure will drop. It also has the place to check makeup cocks, cocks Mayevsky.

And I would start by checking the pressure in the receiver, there should be air pressure not less than 1.5atm, then checked the air (emergency) valve, well, and all the taps. To help you look, turn off all the taps that are in the system and start opening one by one from the boiler and watch the pressure drop over the course of an hour. Perhaps in the system accumulated air and it is necessary to make a boost of the coolant (without a boost pumping the receiver useless).

Navien heating boiler: the best of its kind

Navien boiler is considered the most popular among devices for heating and heating. The firm presents only high-tech models for installation in all kinds of rooms. On sale, everyone will be able to find the device that will serve him well for a very long time. and all at a very attractive price. For heating apartments and small private homes are best suited wall-mounted solutions.

Korean Navien gas boilers are dual-circuit boilers, which have open and closed combustion chamber. They are used for heating and water heating for household and technical purposes. The entire automation system and documentation is available in Russian, so that everyone can study the manual without problems and successfully save on heating costs by continuously maintaining the right temperature in the premises. Uninterrupted and safe operation of the boiler is possible even in conditions of frequent power failures. In case of voltage fluctuations in the network, involving a protective system SMPS, after which the boiler continues to work properly. In particular, thanks to this function, these two-circuit boilers have a long service life, without breaking and requiring subsequent repair.

The setting is simple: hold down the radiator button until the “house with thermometer” image appears. While it flickers, enter the desired values. Set the required parameters with the minus-plus buttons. Temperature range. 10 to 40 degrees. The settings are automatically saved.

It can be adjusted by pressing the heatsink icon button. To set the desired temperature range use the plus / minus buttons while the heatsink icon is blinking. The settings are automatically saved and displayed. Temperature range 40-80 degrees.

Setting the gas pressure of navien boilers

Set the DIP switch 3 on the control board to ON, which will correspond to the minimum load.

Set the minimum gas pressure according to the table using the screw for setting min.Pressure (Increase. counter-clockwise, decrease. clockwise)

Set DIP switch 3 on the control board to OFF (Basic state)

6.Set DIP switch 2 on the control board to ON, which corresponds to the maximum load

Set the maximum gas pressure according to the table with the screwdriver (Increase counterclockwise, decrease clockwise)

Disconnect the diffmanometer hose from the gas valve connection

Set the DIP switch to position OFF (Basic state)

Check the tightness of the gas valve (nozzle). If you hear abnormal noises, check the boiler for gas leaks.

The material was prepared by a worker from heating-mtsensk Warm House.

Hello! Can you tell me whether it is possible to programmatically reduce the boiler output and if so, how to do it??

It is unlikely you would be able to do this.к.This is determined by the model of this particular boiler. (imho)

tusat wrote: Is it possible to reduce boiler output programmatically and if so, how to do it?

And the Fondital Tahiti 24CTFS has it?

tusat wrote : Hello! Can you tell me whether it is possible to reduce the boiler power and if so, how to do it?

The power of the boiler can be reduced to 13 kW.No loss of power on the DHW. To do this you set in a certain position the DIP.switches #9-10 on the boiler control unit.The settings for the different outputs are given in the user manual.

After installation check and adjust if necessary the gas pressure at the burner MIN and MAX.according to the installed power.

It’s true that without losing power to DHW? The maximum pressure on the burner at 24 is 88 and 16 is already 43, are you saying that with this difference the DHW will heat the same?

In domestic hot water preparation mode, the wall hung boilers automatically switch to maximum output.

How can it switch if it is jammed, t.е. Ordered no more no more? If it has a provision for adjusting the maximum heating output, usually it is software, knobs and buttons, then yes, and if you limit the supply with a valve, then finita la comedy.

Mws wrote: Boiler output can be reduced to 13 kW.Without loss of capacity for DHW. To do this, set in a certain position DIP.Switches Nr. 9-10 on the boiler control unit.The settings for the different outputs are given in the user manual.

After installation it is necessary to check and adjust if necessary the gas pressure at the burner MIN and MAX.according to the installed power.

Installing dips.set the maximal gas pressure range on the burner. Exact adjustment is done by turning the resistor.It is located next to the DIP. For DHW operation the boilers are set to 13-16-20 max.The pressure on the burner corresponds to 20kW.Minimum-11-16mm. 10K-13K-16K-20K-24K is the same boiler (Korean version).Similar to 35K-40K. For the European style (Coaxial) boilers, the 24K has a bigger secondary heat exchanger.

Clamp the maximum heating output without losing DHW is possible on any modern boilers.

Read also: How to lay insulation on the ceiling from the inside

Heating units with Korean “roots”, Nawien, are often used in private country houses and in apartments.

What is the reason for such popularity, what are the design features of the equipment and what kind of difficulties can the consumer face, buying a gas boiler Navien.

Instructions for safe use (operation), model selection and proper care. We will tell you about it further.

Navien produces devices of different capacity, designed to provide heating for gasified homes. However, the technical features of the models allow you to transfer them to an autonomous gas supply, that is, to connect to cylinders.

A wide range of models allows you to choose the model for all needs and capabilities.

  • Wall-mounted and floor-mounted;
  • Single-circuit and with hot water supply;
  • with atmospheric and closed combustion chamber;
  • With different size of heating output (three options: 20, 25, 32);
  • with different chimney diameters;
  • And of course models differ in power and dimensions.

The devices have an elegant appearance, fit well into the kitchen or any other interior.

Safety systems, which are equipped with boilers Navien:

  • Modulated turbo boost.
  • Protection against overheating of the coolant.
  • Special chip (SMPS) protects against 30% power surges.
  • Remote control with a temperature sensor, allowing you to keep t constant and adjust the operation of the boiler to special circumstances.

Modulated turbocharger. The system is based on the interaction of combustion air fan and pressure sensor (APS).

The intensity of fan rotation varies in proportion to the amount of gas supplied at a given moment. This allows you to save resources and increase efficiency without wasting fuel.

To the choice of such equipment as a gas boiler, the owners take seriously. Information about the gas boiler Baxi, the manufacturer, as well as the models of units, read on our website.

Read about the purpose of the air valve for heating here. Functional principle and design features.

And in this topic https://microklimat.pro/systems-otopleniya/elektricheskoe-dachnogo-doma.Consider the options for electric heating of a private home. Types of electric heaters and electric boilers.

The device and the main elements of the boiler

It is important to know your boiler in order to perform the simplest steps to maintain it. Although the model may differ from model to model, you can find the basic elements in the case:

  • combustion chamber;
  • heat exchanger;
  • expansion tank;
  • gas burner;
  • circulation pump;
  • control unit.

Read also: How to turn down the heat in the radiator

Particular attention should be paid to the device of the lower part of the body, as here is the connection of the inputs and outputs of the circuits, and there are other important details.

Closer to the wall, there are 4 connecting pipes:

There is a hot water filter in front of the return inlet, and even closer there is a drain plug.

There is a make-up valve in front of the DHW outlet, which fills the system with water.

If the temperature continues to drop and it reaches.6 °, the burner is triggered, which heats the water to 21 °.

Modes of operation

Like many heating devices, boilers Navien have a winter and summer modes of operation. On the display, the button to change modes is indicated by the icon “Snowflake” and “Sunshine”.

By pressing this button repeatedly, you can change the options:

Adjust the temperature of the coolant on the remote control can be when the display lights up with the heating icon.

In some models, to do this, it is necessary to press the button “Heating mode”, in others, turn the knob with this pictogram.

Blinking radiator icon means that the figures you see show the set t of the heating medium.

If the “radiator” is simply lit. the actual temperature in the heating is displayed.

After selecting “radiator”, the “” or “-” keys must be pressed to increase or decrease the temperature. A few seconds after the desired temperature is set, the radiator icon stops flashing, and the display will show data on what t coolant now, and the device will begin to gradually heat it (or cool it down) to the selected.

Adjusting the temperature of the hot water supply

To increase or decrease the hot water temperature, press the faucet icon on the remote control.

By turning the knob, or adjusting the temperature with the “plus” and “minus” buttons, you can set the desired level of heating. It is advised to do this not during the showering, but beforehand.

Adjustment step is 1°C. Limits within which the temperature changes: from 30 to 60 ° C.

Precautions

The room where the boiler is located must be well ventilated.

Gas cylinders, if used, should be stored in a separate cool room.

Do not dry the clothes on the gas heating pipes.

Mains power supply parameters must correspond to the requirements of the particular model (e.g., 220V, 50 Hz).

The appliance must be plugged into a separate socket (no other appliances plugged into the socket), extension cords and adapters are not permitted.

Do not touch the housing with wet hands or plug it in.

The appliance must be in a protective casing when in operation.

Do not install or repair the gas equipment yourself. this is the work of public services. Once a year, these services will conduct a preventive inspection of the boiler.

If bubbles appear, turn off the gas valve immediately, vent the appliance and call the emergency service.

Cleaning the outside surface of the boiler body

Do not clean the machine when it is in operation. To clean the housing, de-energize it, turn off the gas and let it cool down.

Read also: What is the thickness of mineral wool to insulate the house

After that you can wipe the tap with a soft cloth or a sponge.

Filling the boiler and the heating system with water

Error code 02, indicates that an attempt was made to start the boiler, but there is no water in the system, or it is not enough. What to do:

  • The appliance is unplugged and the gas supply is shut off.
  • In the bottom of the boiler, among many other elements, you must find the make-up valve. Turning it counterclockwise opens it and clockwise closes it.
  • When the valve is open, watch the pressure gauge readings. Close the tap when it shows 1.3. 2 bar.
  • Now the boiler is reconnected, the gas is supplied and the boiler is started.

Do not worry if error 02 reappears. This can be caused by the fact that after bleeding the air (which is automatically performed at start-up), the water level is again insufficient. The filling operation must be repeated.

Drainage of water from the boiler and hot water system

If the boiler will not be used for a long time (especially in winter), it is advisable to drain all water from the heating and DHW circuits. What to do:

  • De-energize the unit and turn off the gas valve.
  • Heating system valves (2 pcs.) and cold water.
  • Open the tap that you usually use (over the sink, for example) and drain the hot water from the system.
  • The tap in the DHW system is closed.
  • At the bottom of the housing, open the plug and drain the heating water.

Cleaning the heating water filter

The filters collect all impurities in the water.

Periodically they need to be cleaned, for this purpose:

  • Drain the water (see “Drain the water” on page 31). previous paragraph).
  • Wait for the equipment to cool down completely.
  • The filter is located near the drain plug. To remove it, first remove the mounting bracket, then pull out the filter itself.
  • Wash it under pressure, with clean water.
  • Then assemble in reverse order.

If the filters are not cleaned in time, the boiler will overheat.

Possible malfunctions and troubleshooting

  • 01. overheating (check if the pump works and the filter is not clogged).
  • 03. No gas (check whether the tap is open).
  • 04. false flame signal (check the gas valve, replace the electrodes or the board).
  • 05. 06. short circuit on the temperature sensor or breakage.
  • 09. fan defects.
  • 10. Problems with smoke exhaust (check if the fan works properly, if the chimney is not clogged, correct connection of the fan tubes, the reason could also be a gusty wind).
  • 013. Short circuit on the sensor of heating water flow.

If the boiler does not produce errors, but works much worse, the cause could be a clogged filter or air circulation in the system.

Boilers Navien, like any other appliances like good care and competent handling. Regular checks and service inspection will help to avoid failures.

The installation of an internal electrical network. a responsible stage in the arrangement of a new building. Electricity in a private home with their own hands. how to properly make the wiring? Read advices of professionals.

Recommendations for making a gas burner for the boiler with your own hands can be found at.

Features of functionality of boilers brand Navien

Boilers manufactured in South Korea with the Navien logo are in the lead in ratings based on the opinion of service technicians for a reason. They operate reliably and according to standards that offer an impressive list of features for comfortable operation.

adjusting, pressure, boiler

Advantages that gas-fired heating unit owners can take advantage of include:

  • Frost protection. Stable system that prevents the formation of ice jams in the pipes and the unit. When the ambient temperature drops below 10º, the circulation pump automatically activates, and when the temperature drops below 6º, the burner starts up.
  • Protection against power surges. Safety and continuous operation of the unit is ensured by a device that prevents malfunctions and stops. SMPS (Switchet Mode Power Supply) chip integrated into the microprocessor triggers in case of power supply fluctuations.
  • Protection against low pressure in the gas supply line. Plants survive pressure drops in the blue fuel supply system without their malfunction. Does not stop working even when the head is only 4 mbar.
  • Use in case of a drop in water pressure. Boilers from the South Korean manufacturer work well if the cold water inlet pressure drops to 0.1 bar.
  • Unique heating technology. The equipment is supplied with a remote control unit equipped with a temperature sensor. Readings obtained are instantly transferred to the boiler, which switches on and off in accordance with changes in the temperature background within the object to be treated.

In addition, boilers brand Navien equipped with perfectly functioning automation and a wide range of security systems that interrupt heating of coolant and sanitary water in the case of emerging or threatening situation.

To control the water pressure within the boiler, it is equipped with a manometer. There is a safety valve that allows you to reduce the head if it is higher than the manufacturer’s regulated norm. To avoid overheating, filters are installed for both heating, water and gas.

| Denial of responsibility | Contacts |RSS