CL error on LGEN

TCL air conditioning errors: the specifics of decoding a malfunction code and repair routes

Agree that any (even the most reliable) technique can break. TCL air conditioners are no exception. During the launch or work of these split systems, various problems may occur. They are quickly determined by the internal system of self.diagnosis.

Some errors of TCL air conditioners can be eliminated without involving professionals, and some require contacting the service center. Based on the indication on the display, the owner of the split system can determine the nature of the malfunction and draw up an approximate plan for solving the problem.

We will talk about how to identify a violation by deciphering the signal encoded by the manufacturer. I’ll tell you which way to go to correct the situation. Our recommendations will help to eliminate the problem and extend the life of climate equipment.

Varieties of faults of air conditioners

TCL Chinese air conditioners have proven themselves in the world market as an inexpensive and reliable climate technique. But periodically and they become unusable and require comprehensive repair.

All malfunctions of the tcl split systems can be divided into:

  • errors of voltage sensors, current or temperature;
  • Eeprom firmware;
  • problems with the engine of the inner block;
  • changes in interblord connections;
  • Errors of emergency stop.

The fact that the device fails in the operation of the device can be found out thanks to indicators on the air conditioner and split systems or information that was displayed on the display. T.e. Sometimes the LEDs of timers, previously burning with even light, suddenly begin to blink (randomly or in a certain order), and sometimes-a letter-civilian combination appears on the display.

It is important to correctly identify the combinations of letters with numbers that appeared on the air conditioner’s display in order to decide on the repair and completely fix it

When an error indication appears, a lot depends on when exactly the malfunction arose. If the air conditioner breakdown was detected during the installation of the device (and the representative of the company accredited by the manufacturer of the company is engaged in the installation of the device), the owner of the split system may require replacing the product.

If the air conditioning violations occurred a few months or years after installation, the device will need to be repaired in the service center or repair it on your own.

Review of LGEN air conditioners: error codes, wall and mobile models

LGEN is a Swiss brand that, despite its young age, has already won the sympathy of a huge number of consumers. LGEN air conditioners are produced at factories in Turkey and China. This article will consider all the main characteristics of this equipment, classification of the lineup and consumer reviews.

The climatic equipment of this brand is produced in China and belongs to the budget segment of the market. Split systems Leng are ideal for apartments or small office premises.

A company engaged in the production of equipment for air conditioning of this brand makes them in 2 options:

error, lgen

Consider more detailed information about each type of systems, their place of application and the main technical and economic characteristics.

Wall split systems

These systems are able to work in the following modes:

Lenge wall air conditioners are mounted to control microclimate in small rooms. This type of equipment refers to the budget segment and has all the main functions for this class (heating, cooling and ventilation). As for performance, the devices are able to create an air flow with a volume of 15.83 m 3 per minute. Since it is this type of equipment of the company that is extraordinary demand, we will consider the main technical characteristics of the most popular models.

Ремонт сплит системы своими руками/ошибка Е5/внешний блок не запускается

equipment identification LGEN AL-20WND LGEN AL-40WND
Air flow performance, m 3 /min 6.33 9,167
Useful power in air conditioning/heating mode, kW 1.98/2.14 3.46/3.61
Energy consumption in cooling/heating modes, kW 0.626/0.616 1.071/1.052
Ventilation mode
Intellectual system of self.diagnosis
Maximum noise level, dB 39 40
Nominal area of ​​the room, m 2 21 36

Monoblock air conditioners LGEN

This equipment can be mounted both in a small office, and in an apartment or house. Of course, these systems are not intended for servicing large premises, however, with their main tasks in heating, ventilation or air conditioning, they cope with 5.

Monoblock systems, like wall.mounted air conditioners of this brand, are controlled from the control panel, the purpose of the buttons of which will be considered in the next chapter.

Instructions for the control panel and air conditioners LGEN

In most cases, this technical documentation is supplied with the air conditioner. However, there are often situations when the instructions for the remote control Leng for some reason are lost.

Instructions for manual selection of codes.

For manual tuning the universal remote control of the air conditioner, click on the S (Select) button. Next, you need to find the brand of your air conditioner in the table and select the first code from the table. Then enter the code using buttons with numbers on the remote control. Then press the S button again, and now confirm your choice by pressing the OK button.

Carrier Dc Inverter air Conditioner CL Error Code Fault And Solution

Now you need to check the air conditioner from the remote control in all modes. If the main functions do not work, then in this case you need to re.make the first step, but now you need to enter the next code from the table.

Automatic setting up a universal air conditioning control panel.

For automatic settings for 30 seconds, press the S (Select) button, until in the lower right corner of the remote control, the signal icon in the form of waves will not appear and in the lower line of the PDU indicator, the 4-digit number from “0” to increases to increasing. PDU will be directed towards the IR receiver on the internal block of the split system. After the split system makes a sound, press the S button, and then the “OK” button.

Check the air conditioner from the remote control at all modes.

If the main functions do not work, then press the S button and arrows in the upper right corner of the PDU keyboard change the code on the screen one unit. Then click S, then OK. Repeat p.four.

User reviews

Like all equipment, LGEN air conditioners differ in both positive and negative reviews.

Positive reviews

  • Affordable pricing policy.
  • Works in all modes (including in air ionization).
  • Rapid cooling of the room up to 21 m 2.
  • The presence of an inverting function that allows you to control the compressor operation.
  • Easy installation and the possibility of transportation (monoblock air conditioners).

Negative reviews

  • A bulky external block.
  • An uncomfortable control panel without backlight and with a folding panel that easily breaks off.
  • Lack of a service center, since the brand has not yet been developed.
  • It is difficult to find spare parts and consumables for maintenance.

Mitsubishi-Electric air conditioners | Malfunctions of split systems, error codes

Damaged thermistor

P1 The abnormality of the termistor at room temperature (RT1) 1) poor contact of thermistor 2) damaged thermistor 1) check the termistor. 2) Measure the resistance of thermistor. Normal resistance should be the following. 32 ° F.-15k | 86 ° F. four.3k 50 ° F. 9.6k 104 ° F. 3.0k 68 ° F. 6.3k, if the resistance is normal, replace the internal advice of the dispatchers. P2 The abnormality of the internal termistor of the coil (RT2) P3 signal transmission error (the distant dispatcher does not respond to the internal signal of the dispatcher.) 1) poor contact of the transmission wire 2) the circulation of the transmission/receipt of the signal is wrong. 3) the wrong operation due to the noise wave is emanated by other devices

1) Check the transmission wire. 2) coordinate with another distant dispatcher. If “P3” is still indicated, replace the internal rule. If another checkered code appears, replace the original remote controller. 3) a short circuit between and from CN40 and attach CN40 to the following units. The second unit in double control is the second and third units in triple control of the Sub unit in the control of group P4, the abnormality of the leakage sensor 1) poor contact of the transmission telegraphes

Settings of configuration of any air conditioner

P.S. If in the room the current temperature corresponds to the configured, then the air conditioner will not be cold (or warm depending on the regime).

Icons and buttons on the inner block of the split system

Almost all internal blocks have one “magic button”, with which you can turn on the air conditioner with automatic setting. Usually it is inconspicuous. located under the front cover of the block on the case or on the display. Denoted by “Auto” or “On/OFF”. It is impossible to configure the necessary parameters using this button. you will need a remote control, at least universal (if the full.time is lost). Read more about this hidden button by the link below (for an article about turning on the air conditioner without a remote control).

Instructions for setting up air conditioning in various modes

If you need to turn on the air conditioner in a certain mode, then my site already has all the instructions:

The buttons and functions considered in this article are most often found on the remote controls, but “sophisticated” remote controls are also found, where there are also the same options, only unusually indicated. Examples: Round remarks on LG Stylist, also on the remote controls of Electrolux incomprehensible designations and others.

This is perhaps all If the article was useful for you, then leave Комментарии и мнения владельцев!

Self.diagnosis of air conditioning LG

Difficult working conditions, intensive loads or incorrect calculations when designing the entire air conditioning system can adversely affect the premium class car conditioner. However, the function of self-diagnosis, which the climate technique of LG has, makes it possible to detect and neutralize the reasons in time, due to which the device may fail.

The air conditioner independently launches certain diagnostic processes at each stage of functioning, checking the performance of a particular node.

If certain problems are detected during monitoring, the operation of the device is blocked by a control microcontroller, and the device itself issues a specific error signal. It can be presented in the form of a digital letter on the display or display by blinking certain diodes on the block. The number of outbreaks of a separate diode is interpreted as a separate error code.

The specialist should be engaged in the repair of the device. However, independent decoding of the error code will allow the owner to evaluate the complexity of upcoming work in the restoration of the air conditioner

Displaying errors of air conditioners of the LG brand has a certain feature. If the internal self.diagnosis system finds several malfunctions, then first the block gives an error signal with the least serial number. Each subsequent code will be displayed in an increase in order.

error, lgen

For example, if the system has a cliff in the circuit (error C2 or C4) and the fan of the external unit does not rotate (error C9), then the air conditioner will first indicate a break, after which he will sit on the stop of rotation of the blades in the external unit.

Deciphering the blinking of LEDs

As described above, the internal block of the home split complex is equipped with a special diode. If certain malfunctions occur in the air conditioning system, this lamp begins to blink. A flash can be made from one to ten times, signaling a specific error. At the same time, the interval between a series of blinking diode in the air conditioner is 3 seconds.

Error 1 is expressed in a single flashing lamp every 3 seconds and indicates a break or short circuit in the internal block of the split system, which is why breakdowns in the board occur. To eliminate the problem, they check the work of thermores in the internal unit and, if necessary, replace these nodes.

Error 2 (flashing diode twice) signals a similar problem with thermoresistors that are installed in the external unit.

Neutralization of the breakdown occurs in the same way: the temperature sensors of the incoming air or the temperature of the gas circuit tube are checked, but already in the external unit, and they are replaced.

The air thermal attemptor in the air conditioner is far from the most expensive detail. Therefore, you should not be afraid of its replacement, since the repair work of this plan is quite affordable in price

Error 3 (3 flashing) is associated with the installation of the system and occurs when the air conditioner’s work is aimed simultaneously at heating and cooling. It is necessary to check the correctness of the wire connecting, the interlock cable and the correctness of the air conditioner connection.

Error 4 (4 flashes) indicates the launch of the compressor protection system, which is overloaded. To eliminate, check the work of the thermallane of the external unit, fix the indicators of the current load and gas pressure in the system. These measures will help to find out the reason due to which the compressor may fail.

Error 5 (5 flashing) occurs with an incorrect exchange of data between the apartment and external block. With this code, the lines of cables are tested in which a gap or closing may occur. After diagnosis, you may need to replace inter.block joints.

Error 6 (6 blinking) appears after a short.term increase in consumption current in the external unit. In such a situation, all external units and key power relay are checked.

Error 7 (7 flashes) also signals the excess of current in the outer block, but in this case the consumption threshold goes beyond the norm for a long time. For diagnosis, it is necessary to check the pressure of the refrigerant in the system and eliminate the malfunctions of all elements in the external unit.

The high pressure of the refrigerant in the air conditioner of any brand can lead to coolant leakage, which will inevitably cause more serious repair work. In some cases, it is impossible to eliminate such a problem on the spot, so the master will have to dismantle the entire block

Error 8 (8 blinking) speaks of problems in the fan engine. In addition to direct verification of this node, it is necessary to examine the elements of its control scheme and contact terminals.

Error 9 (9 outbreaks) requires checking the 4-year valve.

error, lgen

Error 10 is associated with the closure or cliff, which could cause a breakdown of the thermoresistor responsible for monitoring the control of the body of the built.in compressor. After diagnosis, the thermorezistor is most likely to be replaced.

What the errors of split systems LG say?

In addition to flashing LED codes of typical malfunctions of the air conditioner, LG may have a digital.boom display. Such a system is also present in the extremely popular ART Cool series, represented by elegant wall air conditioners. The value of the decoding of codes according to this technology is largely echoing with the interpretation of the blinking of LEDs.

Typical errors regarding the closure or break of the chain in separate areas have the following values:

  • C1 (CH1). a short circuit in the internal sensor of air temperature or a break in the same circuit.
  • C2 (CH2). a short circuit or a chain break in the temperature sensor of the evaporator.
  • C4 (CH4). cliff or closing in the circuit at the temperature sensor of the capacitor.
  • C10 (CH10). a break or closing in the thermoresistor of control of the temperature of the compressor body.

How to eliminate the malfunctions of the air conditioner LG?

Information about current shortcomings in the operation of the equipment makes it possible to independently eliminate them.

But, unfortunately, the owner of the air conditioner can correct far from every mistake.

In fact, the repair of the air conditioner LG with your own hands is possible only in isolated cases, when errors found during self.diagnosis of the device suggest elementary malfunctions

If the LG air conditioner provides information about complex breakdowns, you should definitely invite a certified specialist-owner. Previously, you need to restart the air conditioner: perhaps after rebooting the error will disappear.

The master will have to resort to the services of the master if the device signals the such malfunctions:

  • problems in the compressor;
  • errors in the operation of units of the electronic control system;
  • refrigerant leakage;
  • improper operation of the electric motor.

The user can independently unlock the blinds if unauthorized objects prevent their normal work. As well as cleaning equipment or planned replacement of filters and solving problems with the power supply of the device.

error, lgen

The latest works are related to the installation of a voltage stabilizer, because often complications in the operation of the air conditioner arise precisely due to the unstable supply of current in electric networks.

It is worth remembering that disassembling the device yourself is extremely undesirable. In addition to irreparable damage, which the owner can cause equipment due to lack of knowledge and skills, you can lose free warranty service.

Conclusions and useful videos

Review of three top models of air conditioners of the Art Cool series is presented in the video below:

In the next video, the master shows how to repair the air conditioner LG during a freon leak:

And in this video, the specialist talks about the consequences of error C9 (CH9)-replacement of the 4-track valve:

LG washing machine error code CL/LG washing machin technical problem

Self.diagnosis of the air conditioner allows you to find a problem in time and maintain expensive equipment. The climatic technique of LG produces high.quality monitoring of internal systems and quickly informs the owner about current problems.

To eliminate most malfunctions, specialist services will be required. However, knowledge of the transcript of typical errors will help the user prepare for the repair of the air conditioner and calculate the approximate cost of future work.

You use the air conditioner Elji and want to share your experience in diagnosing the cause of the malfunction and the way to solve the problem discovered? Tell our history to our readers. the feedback unit is located below.

If you still have questions about errors in the work of the air conditioners of the LG brand, ask them to our experts and other visitors to the site.

Deciphering codes of air conditioning errors of popular brands

Both household and industrial air conditioning systems, for the most part, have a function of self.diagnosis. This function can work in automatic or in a special one if there are problems with the equipment. As a rule, information with error codes can be observed on displays located on internal blocks of the split systems. Thanks to these data, malfunctions are precisely determined, due to which violations in the operation of the air conditioning system have occurred. To independently determine the causes of malfunctions in devices of different manufacturers, you can use the lists of errors of various airborne codes provided below by brands.

In the air conditioning systems, the microprocessor, when some malfunction is detected, blocks the unit starting, after which it gives signals to flashing the LED, which report the error code.

If the system has discovered several problems, then first of all, the breakdown is induced, which has the smallest serial number. After that, there is an indication of malfunctions in an increase in the order. The table provided below indicates LG air conditioning errors and deciphers that each of them means.

You should know: the emergence of similar errors can be provoked by unsatisfactory parameters of the electrical network, or a random failure that occurred in the electronics of the unit. Therefore, do not rush to contact the service immediately, but simply de.energize the device and check the electrical voltage. It is also necessary to make sure that the operation mode is selected correctly. After these checks, you can turn on the device. Most often, this method helps in solving this problem, and it no longer appears.

A set of fault designations found by the microprocessor depends on the model of the unit. There may be another indication for LG air conditioners. in the form of numbers and letters.

Designations of defects of the condenser unit:

Conclusions and useful videos

Review of three top models of air conditioners of the Art Cool series is presented in the video below:

In the next video, the master shows how to repair the air conditioner LG during a freon leak:

And in this video, the specialist talks about the consequences of error C9 (CH9)-replacement of the 4-track valve:

Self.diagnosis of the air conditioner allows you to find a problem in time and maintain expensive equipment. The climatic technique of LG produces high.quality monitoring of internal systems and quickly informs the owner about current problems.

To eliminate most malfunctions, specialist services will be required. However, knowledge of the transcript of typical errors will help the user prepare for the repair of the air conditioner and calculate the approximate cost of future work.

You use the air conditioner Elji and want to share your experience in diagnosing the cause of the malfunction and the way to solve the problem discovered? Tell our history to our readers. the feedback unit is located below.

If you still have questions about errors in the work of the air conditioners of the LG brand, ask them to our experts and other visitors to the site.

Deciphering codes of air conditioning errors of popular brands

The refusal of climatic technology can be caused by various reasons. Knowing the codes of the errors of air conditioners of popular brands, it is easy to navigate the reason for the refusal and begin to perform repair work. Each manufacturer uses its own coding system.

LG air conditioning errors display the following information:

The codes of LG errors are not the only.

The letter designation is used, which is not only to the malfunctions, but also the functionality of a particular model:

Self.diagnostics system of modern air conditioners

New generation household appliances are usually equipped with a self.diagnosis system designed to identify failures and errors in their first appearance. Self.diagnostics system. a single network of sensors that control the state of a particular unit working unit.

When the air conditioner is turned on, the sensors automatically begin work and continue to perform their functions in continuous mode until the device is turned off from the power supply network. Sometimes, to eliminate the failures and errors, the owner of the air conditioner is enough to perform simple actions with his own hand, sometimes you have to invite masters from the authorized General Climate service.

Consider possible errors and their codes in various models of air conditioners and split.GC systems, causes of their occurrence and ways to eliminate. We will try to figure out in which cases your own acts are appropriate, and in which you should invite an experienced master.

GC air conditioners are equipped with a modern self.diagnosis system that supplies signals during malfunctions and errors in the operation of the control module

When changing the working parameters of the node on which the sensor is installed, an error signal is immediately applied to the control module, which is displayed on the device display. If necessary, the control module also blocks the equipment in order to avoid incorrect operation of the air conditioner and its final breakdown.

General Climate air conditioning models can differ from each other. We will try to examine in detail the codes of each model.

Standart series error codes

In various models of split systems, standart designations of errors may differ, therefore, before you start eliminating a malfunction, it is necessary to clarify the exact name of the model of the system of the system and its internal and external blocks in the instructions. Only after that can you begin to decipher the error code.

The exact name of the model of the air conditioning or split system GC can be found in the operating manual attached to the equipment when buying

When deciphering code, error is very important not to confuse burning, flashing and extinct indicators, the accuracy of determining the problem depends on this.

Characteristic violations for Standart 07-18 R22, R410A

In models of split systems Standart 07-18 R22, R410A error signals are supplied using various combinations of light indication.

Operation quickly flashes, Timer is turned off. the fan stop for more than 1 minute.

Operation quickly flashes, Timer is on. a breakdown of a pipe temperature sensor.

Operation is not turned on, Timer flashes quickly. the supply of high voltage to the compressor 4 times.

Air conditioning errors are displayed on the built.in display of the internal unit using combinations of signals of LED indicators

Operation is on, Timer flashes quickly. Eeprom error.

Operation quickly flashes, Timer flashes quickly. the compressor or problem is not included in the electronic fee.

Typical problems Standart 07.18 and 24

Operation slowly flashes, Timer does not glow, Defrost is turned off-the split system in standby mode.

Operation is on, Timer is not burning, Defrost does not burn-normal operation of the split system.

Operation quickly flashes, Timer is turned off, Defrost quickly flashes. 4 times in a row, protection for current overload worked.

HOW To RELEASE C L ERROR CHILD LOCK OF LG INVETER WASHING MACHINE TOP LOAD MODL #T2111DSAM # LG #

Operation is turned off, Timer flashes quickly, Defrost quickly flashes. the fan motor does not start for more than 1 minute.

Operation quickly flashes, Timer flashes quickly, Defrost flashes quickly. a compressor or a malfunction with an electronic fee does not turn on.

Operation is turned off, Timer does not burn, Defrost flashes quickly. problems with a pipe sensor.

When the error appears on the code, it is very important to correctly decipher the combination of light signals supplied by indicators

Operation is turned off, Timer flashes quickly, Defrost does not burn. problems with the air sensor.

Operation is on, Timer flashes quickly, Defrost does not burn. Eeprom error.

Common violations of Standart 24

Operation slowly flashes, Timer is turned off, Defrost does not burn, Auto is turned off-the split system in standby mode.

Operation is on, Timer does not burn, Defrost does not burn, Auto does not burn-normal operation of the split system.

Operation quickly flashes, Timer flashes quickly, Defrost flashes quickly, Auto flashes quickly. 4 times in a row, protection for current overload worked.

Operation is turned off, Timer flashes quickly, Defrost does not burn, Auto does not burn. problems with the air sensor.

In different models of air conditioners and split systems, GC provides for various encoding failures and errors during the operation of technology

Operation quickly flashes, Timer is turned off, Defrost is turned off, Auto is turned off. problems with a pipe sensor in the inner block.

Operation is turned off, Timer is turned off, Defrost quickly flashes, Auto does not burn. problems with the pipe sensor of the external unit.

Operation does not burn, Timer does not burn, Defrost flashes quickly, Auto flashes quickly. protection.

Operation does not burn, Timer is turned off, Defrost is turned off, Auto flashes quickly. (for ligament systems), a communication failure between the external and internal blocks of the system.

Operation does not burn, Timer does not burn, Defrost does not burn, Auto flashes quickly. (for systems without communication) EEPROM error.

STANDART 30-36 breakdowns (internal block)

Operation slowly flashes, Timer is turned off, Defrost is turned off, Auto does not burn-the split system in standby mode.

Operation is turned on, Timer is turned off, Defrost does not burn, Auto does not burn-normal operation of the split system.

Operation quickly flashes, Timer flashes quickly, Defrost flashes quickly, Auto turned off. 4 times in a row, protection for current overload worked.

Operation does not burn, Timer flashes quickly, Defrost is turned off, Auto is turned off. problems with the air sensor.

Combinations of signals of light indicators built on the internal block of air conditioning or split systems report an error in one or another device of the device

Operation quickly flashes, Timer does not glow, Defrost does not burn, Auto is turned off. problems with a pipe sensor in the inner block.

Operation does not burn, Timer does not burn, Defrost flashes quickly, Auto is turned off. problems with the pipe sensor of the external unit.

Operation quickly flashes, Timer flashes quickly, Defrost is turned off, Auto does not burn. Eeprom error.

Operation does not burn, Timer is turned off, Defrost flashes quickly, Auto flashes quickly. a failure in the external unit of the system.

Operation does not burn, Timer does not burn, Defrost is turned off, Auto flashes quickly-a communication failure between the external and internal blocks of the split system.

Disorders in the work of Standart 30-36 (external unit)

On the external General Climate Standart 30-36 block, the malfunctions are given using a certain amount of lighting light diode on an electronic board.

problems with phases (skew, absence, incorrect alternation).

Settings of configuration of any air conditioner

P.S. If in the room the current temperature corresponds to the configured, then the air conditioner will not be cold (or warm depending on the regime).

Icons and buttons on the inner block of the split system

Almost all internal blocks have one “magic button”, with which you can turn on the air conditioner with automatic setting. Usually it is inconspicuous. located under the front cover of the block on the case or on the display. Denoted by “Auto” or “On/OFF”. It is impossible to configure the necessary parameters using this button. you need a remote control, at least universal (if the standard one is lost). Read more about this hidden button by the link below (for an article about turning on the air conditioner without a remote control).

Instructions for setting up air conditioning in various modes

If you need to turn on the air conditioner in a certain mode, then my site already has all the instructions:

The buttons and functions considered in this article are most often found on the remote controls, but “sophisticated” remote controls are also found, where there are also the same options, only unusually indicated. Examples: Round remarks on LG Stylist, also on the remote controls of Electrolux incomprehensible designations and others.

This is perhaps all If the article was useful for you, then leave Комментарии и мнения владельцев!

Text describing the characteristics of the device.

General characteristics
Type of Wall split system
The main modes Cooling / heating
Maximum air flow 7.67 cubic meter. m/min
Power in cooling mode 2500 watts
Power in heating mode 2550 watts
Power consumption in heating 734 W
Power consumption when cooling 779 W
Supply ventilation mode No
Additional modes ventilation mode (without cooling and heating), automatic mode, self.diagnosis of malfunctions
Drawing mode there is
Control
Remote control there is
Switch.on/off timer there is
Dimensions
Internal unit of a split system or mobile air conditioner (SKVXG) 74.5x25x21 cm
External unit of a split system or window air conditioning (SKVXG) 60x49x25 cm
General
Type of refrigerant R 410A
Phase single.phase
Filters of fine air cleaning No
Fan rotation speed adjustment There is a number of speeds. 3
Other functions and features the ability to adjust the direction of the air flow, the function of memorizing settings
The minimum temperature for operating the air conditioner in heating mode -7?FROM

Damage to air conditioners

Here is a list of the most common and common breakdowns and malfunctions among air conditioners. If you have such a breakdown, then you are lucky, this is a typical malfunction for LGENSW-H09B1 and you can ask a question about how to eliminate it and you will be quickly answered or read in questions and answers below.

Damage name description of the breakdown action
Not blowing question
Air conditioning system does not work question
Temperature control does not work question
Warm cold air does not come from the air conditioner question
Air flow regulation does not work question
The control of the fan rotation speed does not work. question
Remote control does not work. question
The timer function is not set question
The indicator is continuously blinking. question
During operation, smells penetrate the room. question
The inscription “Error” appeared. question
There was a noise. question
Smoke comes from the external unit question
Water drips from the connecting tubes of the outer unit question
Ne vklyuchaetsa Ne vklyuchaetsa question
Error E3 When you turn on the error E3 on the display question
Water drips from the inner block question
The air conditioner does not turn on the remote control, the remote control is in good condition. turns on and turns off only from the roller switch question
Error E1 split 30 km, relatives ask) question
Error E4 question
Makes an error F6 help solve at home for earlier question
Lights do not burn on the panel of a working air conditioner question
It turns on With a stuck fork in a socket. the air conditioner itself turns on and the modes switch independently. question
F1 Blocked and off question
The air conditioner worked. Dismantled laying into the garage for two years, set it gives out an error After a rearrangement shows an error E6 question
When turning on, the short and frequent sound signal constantly squeaks question
Issues E5 on the second block question
E6 question
Error E9 Constantly gives it out question
The compressor is turned off It works fine for five minutes, it turns off without catching the desired temperature, then after five minutes the compressor again turns on question
Temperature designation does not change The temperature on the remote control screen is indicated in the Fahrenheites and does not change to Celsius question
E5 question
Makes an error F4 At first, the air conditioner seems to turn on the air and then abruptly stops and the error pops up and all air conditioning does not function anymore question
KSVP140HFDN3 The compressor is not launched by indicators everything is in normal mode question
All three LEDs on the inner block are burning The air conditioner works, but it began to strain that after the prevention, all three lights of the diode on the inner block began to burn, regardless of whether I turn on the slope function or timer from the remote control. question
Error F9 The air conditioner does not even be forcibly launched question
Do not turn on Burning on a score F8 question
Error F8 Oshka F8 What is it? question
Writes E14 Error E14 is not riagen question
The compressor does not start When the air conditioner is turned on, the compressor is not launched if, when the air conditioner is disconnected from the network, pinch the “Mode” button and insert the fork into the outlet, the candidate is turned on, the compressor is launched, it works, the “Snowflake” and 18C ° display and if you raise the temperature question
The capacitor fan is spinning very slowly. When the air conditioner is turned on, the compressor turns on and slowly accelerates the fan. question
Migrates p1 to cool question
P2 and nothing. silence question
Does not start Error E7 is burning question
J6 Disconnects question
Does not start A few seconds after turning on, all characters light up on the display and the air conditioner turns off. Why? question
The first LED is constantly burning, which on the left to the right on the inner block question
Caught fire on the EC display Caught fire on the EC display and the air conditioner does not work! question
Put on the zholta light bulb question
CF and CL display codes What do errors on the CF and CL display mean? question
PF code At all modes it issues PF code. Only ventilation works. question
Heating On the IGC RAS/RAC-07NHG model, when switching Mode does not offer a heating function. (the symbol of the sun does not appear on the remote control), although in the model this function is provided. Why? question
work failure When the air conditioner is turned on on the air conditioner itself, the air conditioner immediately lights up and blink all the icons: on the left.green leaf, yellow and blue; Reference-blue and yellow-Timer. In the middle, it burns without blinking the letter l with a dot. Redisters of code do not give results. Etc question
Error E2 question
5e question
Error C04 Silent question
H1 question
Only “heating” is turned on, there is no “temperature” on the scoreboard, the “sun” is on fire Only “heating” is turned on, there is no “temperature” on the scoreboard, the “sun” is on fire question
The outer block is launched and immediately stopped question
F7 question
Error P12 question
Heating Cold air goes to heating, hook is collected inside the inner block. There is no heat question
error question

About the author

| Denial of responsibility | Contacts |RSS