How long is the water to get into a boiler?

The standard power is 1.5–2.5 kW. Therefore, a capacity of 10-15 liters warms up in half an hour, and the volume of 200 liters in 5-8 hours. For example, take the models “Ariston” and “Termex”. Boiler capacity from 80 to 100 liters.

Water enters the water heater through a cold water pipe and gradually fills the volume of the water heater. Its level rises. She begins to squeeze air out of the tank. This does not need to prevent this and, therefore, the hot water crane in the nearest mixer should be opened, to which the water heater is connected.

Gus Gus. Full Performance (Live on KEXP)

Do I need to block hot water when using a boiler?

Before proceeding with the inclusion of equipment, it is necessary to block the supply of hot water. There should not be a drop from the tap, otherwise the warm, the water heated by the boiler will go into the common pipe.

Open the valve on the “cold” pipe, and then on the “hot”. Now again open the “hot” crane on the mixer. At first, air will go from the husak mixing with water. It must be completely released from the water heater.

The basics of operation of the water heater

The entire process of the boiler is in three stages:

  • Filling the boiler with water from the cold line.
  • Heating this water to the temperature you set,
  • The distribution of already heated water for provided purposes.

When turning off the boiler, you need to restore the usual supply of water from the taps

How to fill in a boiler and turn it on

The sequence of performing the actions necessary for starting work is simple.

    We block the overall hot water supply valve from the main support system. So we will prevent the intake of heated water from the device back into the main pipe.

Before using the boiler, you need to block the tap with hot water on the riser

check, boiler, complete

Using a thermostat, we achieve water heating to the desired temperature

When you run the device into heating mode, make sure that it is most filled with water. The inclusion in this mode of an empty boiler will lead to its instantal breakdown.

If the water in your region is “hard” (with a large m salt), it is recommended to install a magnetic softener at the entrance to the boiler or cut the filter. They slow down the corrosion process and allow you to increase the service life of the device.

How to turn off the water heater

To turn off the boiler, you need to do in the reverse order all the actions performed when it is turned on. That is, to return the usual current of water from the central pipeline to the mixers.

  • Stop the heating program performed by the device. Disconnect it from the network.
  • Close both taps of water (cold and hot) going to the boiler.
  • We leave the water heater in this position until the need for its use appears again.
  • We open the hot water crane coming from the main pipe of the system.

While the heater is in the current mode, in no case turn it off from the mains.

It is undesirable to turn on and off the water heater very often. This can lead to the failure of all automation of the apparatus. If you heat water daily, it is better not to turn off the boiler at all. Its complete shutdown is recommended only in case of prolonged non.use.

How to set up a boiler

The stronger we heat the water in the tank of the boiler, the more water we get the temperature we need when mixed with cold. If the need for hot water is small and you have water meters, it will be convenient to set the temperature mode that allows you to not dilute the water at all. Thus, we will save both water and electricity.

Recommended optimal water temperature. 55 o C. With this degree of heating, the lowest pressure of the pressure of the scale. The temperature below 55 ° C also does not always affect the apparatus well. For example, water in 30–40 ° C is an ideal environment for the growth of bacteria, leading to fungal lesions of the walls of the tank. In such cases, water acquires a difficult to ensure the smell of mold.

The operating conditions of the boiler

If the boiler is planned to be installed in places with a high degree of humidity (bath, bathroom, etc.), it is necessary to protect the external case from the drops of water drops.

The most dangerous part of the water heater is the filled tank. This is a kind of vapor bomb. Therefore, manufacturers set additional boiler protection.

So that the water heater does not explode under any circumstances, it provides for three steps of protection in the form of thermostats (protective valves):

  • To control the boiler operation mode.
  • To respond to heating exceeding 95 ° C. Simults the work of the first thermostat. If he does not fulfill his functions, then he will turn off the device and will not let the water boil.
  • Thermostat that prevents the rupture of the boiler. It is activated only in exceptional cases when the two previously described defense valves did not work.

We advise you to isolate all the internal pipelines of a self.adhesive pipe lining of foamed polyurethane or from another type of polymer.

In the state, the boiler can be in rooms where the air temperature does not drop below 5 about C. Therefore, for summer residents, this option of obtaining hot water supply is not entirely suitable, since it will be necessary to provide the specified temperature regime throughout the year.

Experienced users noticed that if you keep hot water in a boiler, then it is the smallest degree of corrosion processes. In addition, it is much easier to achieve the desired water temperature, without heating it from a cold state.

You can not leave the boiler empty. It is advisable to periodically pass water through the tank, refreshing it. In extreme cases, it is better to give water to stagnate than to allow air there, which will provoke severe corrosion in the tank.

Do not forget to ground your heater in accordance with the instructions in the instructions attached to it.

Which boiler is better to choose: on one or two hets

In the case of a breakdown of one of the heating elements, it is better if there is one more to continue using. If your room has a weak input of the electrical wiring and sometimes you can not turn on one heater at full capacity (relevant for electric heating), the choice remains for two hets in a boiler.

The main water heating element in the boiler is TEN. Magnesium anode softens the scale

But this does not mean that by connecting a water heater with one heater, you will save electricity. Given the heat capacity of the water, the energy costs necessary for its heating do not depend on the power of the heater.

Is it possible to use a heating water heater

When connected, the boiler can be used for heating the room, but only in rare cases. Some plants already make heaters for such purposes. However, they have a serious difference from the devices we are considering.

In these boilers, the input of cold water occurs from below, and hot is heard from above. Such a configuration is due to lifting hot water when the tank is heated upward. From there, the heating scheme becomes more productive. And besides, these heating systems have holes with large diameters (from 5 cm).

How to fill the water heater with water

The boiler has become a real salvation, especially in the summer of the year, when the centralized supply of hot water stops. Installation and connection of the water heater is still half a worker. In order for it to work, you need to correctly fill it with water. Manufacturers write about this stage in the operating instructions, but, as a rule, users pass this section. Then a bunch of questions arise, why and how. In the article, the master plumber will tell you how to fill the water heater with water.

The principle of the functioning of the water heater

In order to understand how to correctly fill the water heater with water and correctly operate it in the future, you should know the principle of operation. Consider the features of accumulative water heaters.

Internal arrangement of the water heater:

Water heating in the tank occurs due to natural convection. The nozzle water pipe and the heater are located at the bottom of the device, and the other pipe is set at its upper part. Cold water comes from the water pipeline through the lower pipe. Since it is heavier than hot, it always remains from below heats up and pushes the hot coolant up. Thus, uniform heating of the entire contents of the tank is achieved. As cold water arrives, hot water through the upper pipe enters the mixer.

Another important point is the presence of a check valve in a boiler. It is necessary so that in the absence of pressure, the water does not go back into the pipes, and the water heater is not idle. This can cause overheating and failure of the entire device. Modern heating units are already supplied with a built.in check valve. But for reliability, you can install an additional external check valve.

After installing all valves, valves and connecting pipes, the water heater is ready for the first filling with water. The cold water hose is connected to the cold water water supply, and the hot water hose to the mixer. It is necessary to make sure that the water heater is not connected to the mains. Next, we check the correct connection of the pipe strapping of hot and cold water, as well as the performance of all safety valves.

After they are convinced that everything is working properly and correctly, you can start filling the internal container with water. You need to drive out air from the inside. To do this, open the faucet tap.

Then we open the valve of the cold water installed on the heater pipe. The aquatic environment begins to evenly fill the container and shake air through an open mixer. The crane will “sneeze” or “hiss”, this is a clear sign that the air comes out of the heating tank. Playing water water water can sometimes contain air bubbles in itself. Therefore, the water must be driven away until the crane stops “sneezing” from the air output. The presence of air in the tank is poorly affected by the exploring qualities of the water heater. Because of them, the water heats up unevenly, which reduces the coefficient of useful operation of the device.

As soon as cold water will pour from the tap without any extraneous sounds, it means that the water heater is filled and ready to work. Now you can block the mixer and check the connections of the pipes for the presence of leaks. If they are not found, you can safely include the device on the network and set the desired temperature of the water filling tank. Do not immediately set the maximum temperature, as this can lead to a breakdown of the thermostat.

How durable the boiler turns out to be its quality and operating conditions, that is, on the stiffness of water and temperature regime. With a careful attitude, the average service life is 12-15 years, for the most expensive models. 20 years.

What to do if the thermometer does not work on a boiler

The main function of the heater temperature indicator is water temperature control. As soon as the water reaches the specified parameters, the temperature sensor is triggered, sending the signal to the controlled module. It does not show the exact temperature, its main task is to convey the degree of heat heating.

Gas Training. How To Test A Boiler Fan. Combi Boiler

If you have just begun to use the water heater to heat the water and observe strong errors: the pointer shows that the temperature is low, and boiling water pours out of the mixer. then it will be better to turn to a specialist.

What to do if the safety valve proceeds

The safety valve carries an important function, it adjusts the work of the entire water heater. When heated, the water increases in volume, which creates increased pressure in the boiler, when this pressure begins to exceed the permissible norm, the spring in the safety valve compresses and opens it. Excess fluid is pulled, then the pressure normalizes. The “leakage” of the safety valve of the water heater is actually evidence of its correct operation. In the process of heating from the safety valve, it can leak up to one and a half liters of liquid.

If the valve proceeds when the device is disconnected, it is necessary to install a reducing pressure gear, since the pressure of your network exceeds the permissible atmosphere 4.

How to turn on the boiler correctly: detailed instructions for those who first use the water heater

From the author: Hello, dear readers! Modern houses and apartments are gradually equipped with an increasing number of different equipment, which is designed to greatly make life easier for the owners and make it more comfortable. Washing and dishwashers, robots, microwaves, microwaves, double boots and multicookers-without all this it is quite difficult to imagine life.

The same can be said about water heaters. Even in houses connected to a centralized DHW system, there are quite often shutdowns of hot water. What can we say about those in which only cold water supply is initially provided. each acceptance of the soul turns into a real quest. This problem is easily solved by water heaters, which provide the opportunity to always have hot water in stock. But people who first acquired and installed this technique have many questions. How to turn on a boiler? How to use it? How to avoid leaks and the like troubles?

All this will be described in today’s article. Many people prefer to master new equipment by the “poke” method. they intuitively press the buttons until they receive the desired (or reverse) effect. Of course, this method also has the right to life, especially when it comes to a fairly simple technique: a vacuum cleaner, a hairdryer, etc. D. But in the case of equipment for heating water, a more responsible approach is required. When using the water heater, you run the risk of getting not only a broken device, but, for example, a flood in the apartment. So let’s look at how to properly start a boiler for its reliable and long.term work.

Launch procedure

So, the water heater was bought. When it is already installed and connected, the question arises of what to do next. But before taking up the click of the buttons, you should check the quality of the connection. You need to carefully examine all the joints. It is advisable to attach a piece of toilet paper to the compounds. It has excellent absorbing properties and, accordingly, absorbs even the slightest drop of water, which you may not see with the naked eye. If the paper after the diagnosis remained completely dry. excellent, move on.

Important: the use of a boiler should be carried out strictly in the presence of grounding! In general, this should be warned by specialists who were engaged in the installation of a water heater. If there is no grounding in your apartment or house, it must be carried out, connect a boiler to it, and only then proceed to the first inclusion of equipment. Otherwise, you will endanger yourself.

The first launch of the water heater is carried out in several steps. It is important to observe the correct sequence.

  • Crush the supply of hot water from a centralized system to the apartment using a shut.off crane. If you do not, then subsequently all the water, carefully heated by the boiler, will go to the common riser. Even the check valve, which is one of the mandatory elements of the water heater installation, in this case will not help. After the shut.off valve is blocked, open the “hot” tap on the mixer and wait until the remaining water from the pipes merges from the pipes. Of course, if your house is not connected at all to the hot water supply system, just miss this step.
  • Now pay attention to the boiler itself. Two pipes are connected to its lower part. As a rule, they have color markings. The blue denotes the pipe for supplying cold water to the water heater (as a rule, it is on the left, but another option is possible), red. for the release of hot. On both pipes there are shut.off valves. Open the one on the “cold”. Water will begin to enter the equipment. We do not include the device on the network.
  • Now open the valve on the “hot” pipe, as well as the corresponding crane on the mixer. At first, air will come out. you need to wait for it to be replaced by a full.fledged flat stream. After that, close the tap on the mixer.
  • Now connect the water heater to the mains and set the necessary temperature regime. The last operation is performed quite simply with the help of special levers or a special control panel. a separate instruction is not needed for this, everything is shown on the very case of the device.

A few words should be said about the optimum heating temperature. As a rule, the range of permissible values ​​of the water heater is quite wide. from 30 to 90 degrees. At the same time, it is worth focusing not only on efficiency, but also on security.

What is a Boiler and How does It Work?

For example, at a temperature of up to 40 degrees in the tank, various bacteria are actively propagated. You will not be able to get rid of them, since they, in any case, will come from a cold water supply system. In hot water, such bacteria either fall asleep or even die (depending on temperature). But moderately cold for them. just paradise. The result of washing in such water can be various diseases.

The best option is a temperature of 55 to 60 degrees. Bacteria in such an environment do not die, but do not multiply, they simply go into a state of animation. In addition, this level of heating favorably affects the service life of the heater, lowering the intensity of the formation of scale. This is optimal from the point of view of safety. water with a temperature of 55–60 degrees does not cause burns in a person, so you can safely entrust the interaction with it not only for adults, but also for children.

As for the 90 degrees mode. it is also necessary, but not for everyday use. Heated the boiler once a week to this temperature, let it stand for two or three hours, and then set the usual mode again. During these couple of hours, hot water will completely destroy all the bacteria, thereby the tank will be disinfected.

Often people are interested in the question of whether it is possible to turn off the water heater at night. Many people believe that it will be more economical, because at night no one washes, and the constant heating of water is wasted. In fact, you should not do this. Firstly, heating the total fluid volume in the “from scratch” tank will require much more resources than the regular restoration of slightly fallen temperature. Secondly, in the morning you will have to wait long before being washed and go to the shower.

If you really want to save, then transfer the boiler at night to low.temperature mode, but do not turn it off at all. Thus, the morning heating time will be reduced, and at the same time the night consumption of electricity will be very small.

Building Ten

According to statistics, the heater in the water heater fails quite often. In each fourth case, the owners are faced with the fact that the device does not heat the water, although all indicators, including temperature sensors, and thermal controllers indicate the correct connection and serviceability of all available wires. It happens that the water heater hits the current, thereby enduring people. Sometimes an automatic function is turned off in the device, causing power supply changes, a malfunction and short circuits throughout the wiring of the house.

The result of the appearance of all these problems is the stop of the functioning of the ten and thermostat. In this case, do not immediately throw the device and call a specialist, you should try to check your own heating element for a breakdown. Only the initial knowledge of physics and several tools are needed.

Limp Bizkit. Rollin’ (Air Raid Vehicle)

Verification rules

Ten checking will not be difficult, but you need to know some of the nuances of this diagnosis:

  • The check is carried out only by a completely serviceable multimeter,
  • It is possible to accurately check the heating element without disconnecting all the connected wires,
  • The joints of the metal and probes of the multimeter should be cleaned of any contaminants, rust and lime plaque,
  • the safety valve must be checked.

All these conditions are binding on accurate diagnosis, so as not to mistakenly recognize the working heating element faulty.

The basics of operation of the water heater

The “short course” of the basics of operation of the boiler can be divided into three parts.

First start

Two stages should be preceded by two stages:

Typical boiler scheme for water heat

We check the correctness of the connection as follows:

  • Make sure that the valve cutting off the internal wiring of the hot water supply (DHW) from the riser is in a closed state. If this is not the case, the water heated by the boiler will be dropped into the riser. The root valve can pass water, and in the absence of pressure on the network, it is not possible to identify this fact in a simple way. To prevent hot water leakage, set the check valve after the valve.
  • Make sure that the check valve is installed in the boiler in the boiler at the boiler. This node holds water in the boiler when the pressure in the cold water supply (HVS) is turned off in the pressure in the highway. In the absence of a check valve or its breakdown, the liquid flows out and the device may turn on “in dry”. In principle, in modern water heaters, security measures are provided for this case, but you still should not risk.
  • A rubber or polymer tube should be worn on the nozzle of the safety valve, the free end of which must be lowered into the sewer or drain tank of the toilet. This valve is not emergency, as many beginner users think. When heated, the water pressure inside the tank inevitably grows, so a small part of it will constantly be dropped from the first minutes of use.

note! The pressure of the safety valve indicates the pressure in which it opens. This pressure should be higher than the pressure in the CVS network. If the latter is too high, which, as a rule, takes place in multi.storey buildings, then at the entrance to the boiler you need to install a reducing gearbox.

It is with this gearbox that water pressure is regulated

The minimum acceptable pressure should be taken into account, in which this water heater can work (indicated in the instructions). This is necessary to pay attention to residents of rural settlements with centralized water supply recorded from the water tower.

The last thing to check is the condition of the cranes with which the boiler is cut off from the systems of the CVS and the DIS. Both should be open.

To fill the water heater, just open the hot water crane on any of the mixers. Thanks to this, network water, partially filling the container, will be able to supplant the air from the remaining volume and fill the system completely. As soon as a flat and stable stream is piled from an open tap, filling can be considered completed.

By distraction or in a hurry, the user can forget about the implementation of this important procedure and turn on the “dry” boiler. Further will depend on the type of device and its condition. If this is a modern model with good electronics, the security system will not allow this mistake, so nothing bad will happen. If the boiler is not equipped with such a system or it has become unusable, its heating element (TEN) will overheat and burn. This does not mean at all that the water heater will have to be thrown away: the heater can easily be replaced, and this part is not at all expensive.

Advice. If the boiler is not equipped with a security system that prevents inclusion without water, install the so.called “dry” heating element in it. This heater is not afraid of “dry”.

Further operation: how to use it correctly and economically

Even with the best thermal insulation, part of the heat generated by the boiler will inevitably disappear into the surrounding space, while each lost watt will have to pay in full. The volume of heat loss is always directly proportional to the temperature difference inside the boiler and outside. Hence the conclusion: you do not need to constantly keep the thermostat at the maximum.

With a moderate consumption, for example, for washing a small amount of dishes or washing, the water in the boiler should be heated so that it does not have to dilute it. It is necessary to install maximum heating only when a lot of hot water is required, for example, for bathing. With such tactics, all the heat loss, and therefore electricity accounts will be minimal. In addition, with a decrease in temperature, the rate of formation of scale is reduced and the rate of formation.

To combat the scope, softeners and additional filters are used

Leaving the house or apartment for several days, the water heater needs to be disconnected. Some “experts” advise not to do this, motivating their recommendations very blurry: they say, the boiler is easier to maintain the temperature at a certain level than to catch it from “zero”. This statement is not true: the amount of heat reported by water will accurately correspond to the quantity of heat loss, and the latter will be less, the less the temperature difference and outside the capacity. In the disconnected device, the water will cool, which means that heat losses will be reduced to zero. If the boiler is left on, heat loss will take place throughout the downtime, and Ten will have to constantly compensate for them (again at the expense of the owner).

But at night the water heater should not be disconnected: the savings will be trifling, and it will not justify the wear of electronics, for which the moment of turning is always associated with short.term overload.

note! If the boiler is constantly operated in an economical low-temperature mode, then at least once every 2 weeks it must be warmed up to a maximum temperature with a 2-hour exposure. Such a measure will prevent the propagation of bacteria, which are especially active in warm water.

Long simple

If the water heater for a long time remains unemployed, it does not need to be poured out of it, since an empty tank is corroding very quickly. After downtime, the container will need to be thoroughly washed to remove the smell of stagnant water, and heat to the maximum temperature with a 2-hour exposure.

Alternative use

The boiler can perform the function of the electric boiler in the heating system. For such purposes, special models with an increased diameter of the pipes (50 mm) and the upper arrangement of that of them through which heated water enters the system. This performance provides natural circulation of the coolant, that is, due to convection alone.

An ordinary boiler, in which the pipes have a smaller diameter (1/2 inch) and are located below, can also be used as an electric boiler, but only if there is a circulation pump.

Launching a boiler after downtime

Usually the “downtime” of the equipment is called a period from two weeks to 2-3 months. At this time, the water heater should be completely disconnected from the electric network and water supply. The period of downtime is not always accompanied by a complete drain of water from the tank and drainage of the entire water supply system, but if you know in advance that for a long time you will not use the boiler, it is better to drain the water from the tank. Then the bacteria hazardous for health will not multiply inside it. The activation button on the boiler housing should also be translated into an inactive state. With a long break in the operation of equipment inside the tank, microbes can accumulate, rust develop.

  • Cross the pipe with hot water supply, otherwise the liquid heated by the boiler after starting will go into the common pipe.
  • Fill the container with cold water from the common riser, and then open the heated liquid output on the boiler (red marker).
  • Lower the water and wait for the appearance of a flat jet indicating the absence of air in the tank.
  • Turn on the water heater itself using the “Power” or “ON” button (depending on the model).
  • Connect the equipment to the power supply system, adjust the temperature parameters and produce trial heating.

If your heater model has a protection and self.diagnosis system, if there are problems, the device will notify them with sound or light indication. In other cases, you need to independently check the condition of the indicators on the indicator panel every 10-15 minutes until the water is completely heated in order to make sure of the full operation of the equipment.

Launching a water heater after conservation for the winter

The scheme of actions here is almost the same as with a less prolonged simple one, but it has a number of nuances. In the realities of winter, the period of conservation for several months involves not only disconnecting water heating equipment, but a complete drain of water from the tank and, if possible, purge the water supply system with an air compressor. Thus, you get rid of moisture residues in pipes, so that in the winter at a negative temperature they do not freeze. After the end of the conservation period, the algorithm of actions when starting the boiler should be as follows:

  • Before activating the boiler, open water on a common pipe and listen: if strange sounds indicate the presence of extraneous objects, pieces of ice or garbage in the pipeline, you cannot include a water heater.
  • If the water in your area is far from the ideal in its chemical composition, contains a large amount of mechanical suspension, has a high hardness indicator or excessive dissolved iron, it is recommended to install a multi.stage filter for wiring before the boiler. This will prevent the wear of the anode rod and the premature failure of the heater.
  • Perform an algorithm of actions described in the “Boiler launch” section, but after heating the water in the tank, do not use it for washing, but lower it well. Flushing will help remove particles of scale, garbage and dust.

If the boiler does not work like before, you should seek professional diagnostics with a visual and instrumental verification of the condition of the equipment.

Is the repair possible?

In some cases, the water heater can be fixed on your own. However, the process is not as easy as it might seem to seem to.

The first step is to understand the cause of the malfunction. To do this, you should prepare and take tools that may come in handy during the inspection:

After that, be sure to disconnect the device from the mains, pour the liquid. The device of the device should be empty. Only after these manipulations proceed to inspection, revealing the causes of breakdown or leak.

In some cases, the problem is solved by a small repair. Others will need a complete replacement of the water heater with a new. It is advisable to do this earlier than the warranty period expires.

Here’s what to pay attention to when examining:

  • Water leakage appear in the butt areas of the pipes. The cause of the malfunction is the leakage of the water heater tank. Repair is impossible. The boiler will have to be changed.
  • The course is observed in the upper part. If the device was regularly taken by the device, they replaced the magnesium rod in time, and there is still there, the repair will not help. Have to buy a new boiler. Also, the entire water heater must be replaced if it has an old magnesium rod, which was not replaced during prolonged operation. This provokes the rotation of the tank (in the case of an unamalized inner surface).
  • The tank cover flows. In these circumstances, a new heater is put.
  • Leakage directly in the tank. The most unpleasant situation is that the leak comes from the bottom of the tank. The most likely scenario is the accumulation of deposits that corrode the bottom of the tank. The repair is impossible. The fact is that the water heater is a holistic device with a single body and enameled internal walls. When an enameled surface is disturbed, it is not subject to restoration.

The first place that the plumber will check is the drain valve. It is located at the bottom of the tank. Is responsible for draining the sediment from the water heater. The valve is easily replaced, so this situation is the simplest.

It is important to remember that not every small puddle of water found at the base of the water heater is a result of a leak. On the pipes and devices that surround the water heater, condensation can form. As it accumulates condensate, the liquid will drip, accumulating on the floor. This is especially true in basements or in raw weather.

The boiler design and the system of work are more difficult than to think. For this reason, the most optimal way is to order repairs from specialists or purchase a new device.

How to extend the life of a water heater

The first condition is to carefully read the instructions for installation and operation. It is provided with the device.

It is worth paying attention to the following recommendations:

  • Before installation, you need to take care of grounding, the presence of an anode from magnesium, as well as prepare a protection valve.
  • Before starting the installation process, it is important to find out the pressure indicators in the device. Normal. less or equal to two atmospheres. If the number exceeds three atmospheres, the pressure will need to be reduced. To do this, a gearbox is put in front of the water heater. It protects against increasing temperature.
  • The recommended temperature in the device is not higher than 50 degrees.
  • From time to time the device must be cleaned. Optimal. from 2 to 3 times annually. Particular attention is paid to the rod.
  • Connecting a device with a water supply system is better through a magnesium filter. It is acquired separately. The filter will significantly loosen the stiffness of the water, reducing the volume of harmful impurities.

Thus, if even a minimum leak in the water heater is detected, you need to quickly take care of solving the problem. Regardless of the degree of damage, it is always recommended to cause professional plumbing and check the source of leakage.