How to remove relay from the Beko refrigerator motor

How to remove the relay in the beko refrigerator

The most necessary device, both in the apartment and in a private house, is the refrigerator. And it is difficult to disagree with this statement whether so? It is difficult to find a dwelling where it is not. Like any devices, refrigerators can break. But there are situations when a breakdown can be diagnosed on your own.

Almost all household refrigeration equipment is equipped with a single.phase engine. To start it, you have to use the starting device. If this simple but important detail fails, then the compressor will stop starting. But, knowing the principles of the device, you can determine the problem and fix it.

This article will talk about how the starting relay for the refrigerator works and the signs of its malfunction. We will tell you how to install problems in the operation of refrigeration equipment. The videos we presented will help to understand the principle of operation of the starting device, as well as if necessary to identify its malfunction.

The principle of operation of the starting relay of the refrigerator

The control type mechanism that controls the operation of cooling equipment, small in size, is located in the immediate vicinity of the compressor. There are two types of relay:

The last variety is of two types:

  • Current. It turns on when an electric current reaches a certain value. The engine consumes this electricity, and when it overheating, the relay turns off the power. When the motor cools to a certain temperature, the trigger mechanism again includes it.
  • Tokovo-heat. The starting relay is triggered according to thermal indicators and electrical current values. A working engine consumes electricity passing through a spiral, which heats up slightly, without affecting the biometric plate.

There are several types of launch relay, but there are two main functions:

On the principle of operation, devices are distinguished:

The posistor, the type of thermal resistor, together with the capacitor located between the tires of the working and starting winding, are the main details of the tablet. The last part of the structure provides a phase offset that includes the refrigerator compressor engine.

The electric current in the maximum value proceeds through the winding, heating the position and increasing its resistance. Electricity supports a type of thermal resistor in a heated state while the compressor works.

The main working detail of the induction relay is a solenoid, the coil of which is connected to the working winding of the compressor engine. The electric current in the maximum value passes along the coil, creating a strong magnetic field. The force of attraction of the latter is attracted by conductive contact, closing the circuit.

A set of speeds with a rotor becomes a signal to reduce current strength that reduces the effect of the magnetic field. This allows the core to restore the original position by opening the contacts. A prerequisite for the operation of the induction relay is a strictly horizontal location of the part inside the refrigerator.

refrigerators repair master in Togliatti ☎ (8482) 615-505

Signs of a defect of the thermoregulator: the refrigerator does not work, the compressor does not start, when you rotate the thermostat handle clockwise, the situation does not change or when installing the thermostat in the greatest cooling mode, the compressor works with a small working time coefficient, the temperature in the refrigerator is increased. In the refrigerator, the refrigerator lighting lamp burns.

The temperature regulator is designed to turn off the compressor of the refrigerator when it reaches the specified temperature. The sewfty of the thermostat and the capillary is filled with freon, when the temperature decreases, the pressure in the bellins drops, it compresses and open up the contacts “3”. “four”. through which the compressor is powered. If there is a defect. a freon leak from a thermoregulator’s bellows will be the same. the refrigerator will turn off only now forever, it will also occur with a defect in the contact group of the thermoregulator.

How to get to the thermoregulator case? It is located directly by the switching handle of temperature modes, depending on the refrigerator model, you will need to remove a certain number of plastic parts. Be careful and do not damage them (the one who projects the refrigerators never repaired them).

If the thermoregulator housing is available, call the contacts “3” multimeter. “four”. If there is no chain. It is necessary to change the thermostat. For greater confidence, you can put bugs (with a cross.section of the working wiring) between the wires on the contacts “3” and “4” if the refrigerator is turned on, everything requires replacing the thermoregulator.

Marking is indicated on the device case. For one.compressor refrigerators with two doors, this is usually 1331m, K59. Danfoss 07786496 for freezers. there145, K57, K56, for single.door (single.chamber) refrigerators with a freezer compartment. THERE.112, K50

b) change the start-protecting relay of the refrigerator motor-compressor. Signs of a defect. The refrigerator does not turn on, the refrigerator turns on for one, five minutes and turns off. Before changing the relay, it is necessary to check the compressor. defective. To do this, measure the resistance of the windings of the electric motor. working and starting, and make sure that there is no cliff or interitaevo circuit on windings. The resistance of the windings must correspond to the face value.

If there are no discrepancies, change the relay. If on the refrigerator two compressors as a control relay can be used to check the launcher.protective relay from the second compressor.

The refrigerator earned well done. If it turned out that the thermostat and the trigger relay are working, and the reason for the refrigerator fails, the other remains only to call a specialist-special equipment and tools are required.

Methods for diagnosing a malfunction

Diagnosing a relay breakdown is very simple, because this affects the work of the entire refrigeration equipment. Signs:

  • the refrigerator engine does not start;
  • The engine starts, but it works for a short time (no more than 10 minutes), after which it turns off;
  • The engine hardly starts, but cannot work in normal mode.

Important! Sometimes the engine continues to operate in the same mode, without disconnecting.

You can identify the relay malfunctions when the contacts are disconnected from it and connect them directly to the engine. A more time.consuming process is a complete replacement of the element.

Diagnosis can be difficult. This is due to the fact that the relay malfunctions by their signs are very similar to the manifestations of the leakage of the refrigerator.

Replacement instructions

If during the diagnosis it was found that interruptions in the refrigerator are associated precisely with the relay breakdown, the part should be replaced. You can turn to professionals, but even a newcomer can be replaced. It is enough to adhere to all the recommendations of specialists and carry out all the manipulations extremely carefully.

  • Open a special cover or get to the motor compartment in another available way.
  • Determine where the relay is and remove the protective valve from it.
  • Gently disconnect the part from the engine contacts.
  • Carefully examine the launch box. It is important that it does not have mechanical damage.
  • Using the multimeter, check the resistance of the posistor and thermal protection.
  • If it was found that the part was burned out, it is worth checking the resistance of compressor windings.
  • With the permissible resistance, install a working mechanism.

After all manipulations, it is important to check the refrigerator’s operation. You need to connect it to the network and listen to how the motor operates. If everything is in order, the part was replaced correctly and it was in its breakdown that the cause of the malfunction of the entire technique was. If the problems remain the same, the case is in other elements that failed. In this case, it is better to attract a professional master.

Step.by.step instructions for repairing nodes and refrigerator systems

After you have decided on the cause of the malfunction, you can proceed to eliminate it. Consider the most common options.

Elimination of a malfunction with a thermostat

Depending on the specific model, the thermostat can be located both inside the refrigerator and outside. With the internal location, it is enough to remove the temperature adjustment handle and remove the thermoregulator housing.

In the refrigerators Samsung, LG and other foreign brands, you can also check the thermostat under the panel of reducing and increasing the temperature of cooling. But it is placed on the outer side of the camera. You need to determine the performance:

  • Disconnect from the network;
  • Completely defrost;
  • Turn on the refrigerator for maximum freezing, placing inside the thermometer and wait a couple of hours, if the device shows not 5. 7 ° C, then the replacement is inevitable.
remove, relay, beko, refrigerator

To fix the refrigerator, it is enough to purchase a spare part and install a new in return for a faulty part.

Search for leakage and replacement of a refrigerant

The leak can be found with several methods:

  • Soapy solution. available in the case of a weak leak and the presence of pressure of liquid refrigerant in the system. In this case, access to all pipes is provided. the protective cover of the case is removed, the evaporator is defrosted. At the place of gas release, the soap solution will foam.
  • Dye. is used where the pressure in the circuit does not allow the use of soap solution. The dye is added to the liquid freon and launched into the system, after which a characteristic color appears in the leakage site.

Before downloading a new gas from the system, the remains are pre.removed with a vacuum pump, when blocking the blockages, additional cleaning is carried out. Then the refueling is made. Experts recommend performing this procedure and without leakage every 3. 5 years.

Damage to thermal protection relay

In case of violation of the normal operation of the temperature fuse, a premature shutdown of the refrigerator may occur, which is why the threat of engine overheating occurs. For repairs, you will need to remove the relay and disassemble its body, if the reason is in the jammed rod, the issue can be solved yourself, if the winding is damaged, you will have to change the whole detail.

Replacing a faulty compressor

  • Turn off the refrigerator from the network;
  • Tilt the compressor and run the compressor for a couple of minutes;
  • The piercing valve is fixed to the filter-dryer, connect the cylinder to the valve and tighten the piercing valve and open it for half a minute;
  • Instead of a gas station, solder the copper tube;
  • Perform the incision on the capillary tube;
  • Remove the old compressor and install the plugs in the suction and pumping output;
  • Install a new compressor and solder it, carefully inspect the quality of the soldering.

Compressor repair

Elimination of rattling compressor sounds

The noise of the compressor can be caused by the loose fit of metal elements or vice versa, the excessive proximity of certain elements, which is why collision occurs and rubbish.

For repair, it is necessary to tightly fix the casing, in the case of a shaken fastener, put the washers for tight fit and tightening.

Compressor mounting adjustment (shown by arrows)

In case of approaching other elements, it is necessary to adjust the devices itself in the opposite direction or carefully bend the tubes if it is impossible to move the compressor.

Replacing lighting lamps

In order to avoid electrical injury, disconnect the refrigerator from the network. Then open the door and check the condition of the lighting device, for example, in the refrigerators Indesit, the light can be very hot, so you should wait for complete cooling.

E 15 Error Condenser Fan Motor Fault In Beko #fridge #beko #e15 #

remove, relay, beko, refrigerator

To do this, it is not necessary to use the same lamp, but you can find an alternative replacement, but, accordingly, according to the type: incandescent or halogen. The power of the lamp should not exceed 30 watts. But before replacement, it is worth checking the voltage in the cartridge, because the reason may not be in the lamp at all.

Solving problems with temperature sensors

This part is designed to regulate the work rate of the compressor installation. When they fail, the refrigerator will not be able to maintain the desired temperature regime. Quite often, such a malfunction occurs in the Nord refrigerators, they include several such elements at once.

But to independently disassemble and repair at home they will not work, so after removing the sensor, it will require a complete replacement.

Cleaning the drainage system

There are two options for placing the tube. outside the housing and under it. In the first case, cleaning is performed quite simply: remove the phone and rinse it in hot water, soften the accumulated clogs if possible.

In case it is impossible to remove the phone, it should be tried to clean it with a ruff that is included in the kit. If it does not cope, a metal wire is used for repair, previously cleaned by sandpaper. After cleaning the tube, it must be washed with water.

Repair of a drainage tube

How To: LG/Kenmore Compressor Start Relay 6749C-0014E

Alignment of the position of the doors

To adjust the situation, it is necessary to get to the place of fastening, for example, in the LG refrigerators you will need to remove the protective bar, in other models the bolts can be in the public domain. After unscrewing, remove the door, put the puck in the right nodes and set the door to place. If there are such, collect decorative designs in the reverse sequence.

Damage to control

Characterized by the complete silence of the refrigerator, despite the fact that the power chain is completely good. Control board is one of the very complex devices and one of the most expensive. Replacement in the service center will cost three expensive, so it is better to make repairs on your own. For this:

How to remove and replace the relay in the refrigerator

Laun.protective relay is used to facilitate the start of the electric motor of the refrigerator compressor. They also perform the function of protecting the motor from overheating, periodically turning it off. Like other details and nodes of the refrigerator, they can fail. A home master can independently determine the malfunction and replace such a part.

Nodes such as a motor-compressor and evaporator are better not to try to repair yourself. If you understand electrical engineering, you can try to save money and time to contact the service center and replace the launcher of your refrigerator on your own.

Relay is a fairly simple device, and there are few reasons for its failure:

  • Jamming the mobile contact group. In this case, the contacts do not close the circuit. Or, conversely, do not open it.
  • The failure (burning) of the heating winding
  • Loss of elasticity of the bimetallic plate.

Outwardly, the device malfunction is manifested as follows:

  • The compressor engine does not start.
  • The engine operates for a while, usually no more than 10 minutes., And then he stops.
  • The engine begins to work, but does not turn off, although the given temperature in the freezer and in the refrigerator has already been achieved.

To determine what failed to relay, it is recommended to turn off the terminals from it and connect them directly to the engine. If he earned, it was in the relay.

Another diagnostic method is to connect a deliberately serviceable device. If the engine has earned normally, with periodic shutdown in 10-20 minutes, then the working device can simply be left in its place.

Similar features are also observed in the case of a leakage of the refrigerator, which makes it difficult to diagnose.

Before starting to remove the device from the refrigerator, it is worth checking a few more points.

  • Traces of burning or melting of wires and connectors are visible. Such a device is subject to unconditional replacement.
  • The attachment of the device weakened. In this case, mobile contact groups can jam. In this case, the motor begins to vibrate. Should be tightened or replaced by mounting elements.
  • The connectors were ill. Contacts should be cleaned and squeezed.

If in the course of independent diagnostics and repairs it was not possible to achieve success, one should not try to disassemble the refrigerator nodes, especially the motor-compressor. It is better to contact the service center.

Types of launcher relay

Despite the variety of external performance, in modern refrigerators, two main types of launch protection relay are used:

  • Current. Work upon reaching a certain value of the current current. A normally working motor consumes a given current. When overheating of the engine, the current consumed increases sharply, the device works and breaks the circuit, turning off the engine. After cooling the motor, the device resumes its operation.
  • Tokovo-heat. Trigger both when the current value is reached, and when the given temperature is reached. While the engine consumes a normal current, the spiral through which it passes is subject to slight heating and does not affect the bimetallic plate. The higher the current current, the more he heats the spiral. It heats the sensitive plate, it changes its shape so much that it leads to the opening of the contacts through which the electric motor is written.

In the current-heat devices, temperature growth leads to a change in the shape of the bimetallic plate. It is welded from two plates, the metals of which have a different coefficient of thermal expansion. When heated, the bimetallic plate is bending and opens the contact group, turning off the electric motor. After the engine has cooled down, the plate returns to the original form and closes the contact groups, starting the engine again. In addition to the thermal protection circuit, the engine turns on and is also disconnected by the thermostat.

The plate is heated in various ways:

The start.up device also carries out the function of starting the electric motor. To do this, for a short time, a large start.up current is supplied to the engine winding, and after the rotor is folding and starting its rotation, the current is reduced to working values.

Outwardly the device looks like a small box fixed on the compressor casing.

  • Two contacts. phase 220 volts and Earth. Used on synchronous electric motors.
  • Three contacts: launch winding, working winding and earth. Such designs are used on asynchronous electric motors.

Contacts are distinguished by the color of the cables passing to them.

Induction relay of the DHR type are fixed on the refrigerator frame and designed to control the motor-compressors such as DHM. A strong permanent magnet is placed to increase the speed and disconnecting of the engine next to the plate. When the plate, curving under the influence of heat, enters the magnet attraction zone, it attracts it, accelerating the operation. The attraction of the magnet also gives extra time to cool the overheated motor. The cooled plate overcomes the attraction of the magnet and closes the contacts.

RTP type relay has a lower operation current and lower dimensions. It does not require fixing on the frame and is mounted directly on the wires.

You can check the serviceability of a launcher relay by an ohmmeter, multimeter or other available measuring device. The working device has zero resistance between contacts. If the resistance is endless. the device is faulty and it must be changed.

The start.up device works in a single electrical circuit with a thermostat.

The refrigerator user manual indicates which devices can be used for each specific model. This allows you to choose a suitable replacement device, if exactly the same as failed, will be inaccessible.

How to remove the starting relay from the compressor of the refrigerator

Laun.protective relay is used to facilitate the start of the electric motor of the refrigerator compressor. They also perform the function of protecting the motor from overheating, periodically turning it off. Like other details and nodes of the refrigerator, they can fail. A home master can independently determine the malfunction and replace such a part.

Nodes such as a motor-compressor and evaporator are better not to try to repair yourself. If you understand electrical engineering, you can try to save money and time to contact the service center and replace the launcher of your refrigerator on your own.

Relay is a fairly simple device, and there are few reasons for its failure:

  • Jamming the mobile contact group. In this case, the contacts do not close the circuit. Or, conversely, do not open it.
  • The failure (burning) of the heating winding
  • Loss of elasticity of the bimetallic plate.

Outwardly, the device malfunction is manifested as follows:

  • The compressor engine does not start.
  • The engine operates for a while, usually no more than 10 minutes., And then he stops.
  • The engine begins to work, but does not turn off, although the given temperature in the freezer and in the refrigerator has already been achieved.

To determine what failed to relay, it is recommended to turn off the terminals from it and connect them directly to the engine. If he earned, it was in the relay.

Another diagnostic method is to connect a deliberately serviceable device. If the engine has earned normally, with periodic shutdown in 10-20 minutes, then the working device can simply be left in its place.

Similar features are also observed in the case of a leakage of the refrigerator, which makes it difficult to diagnose.

Refrigerator Not Cooling. How to Fix. What to Check [2020]

Before starting to remove the device from the refrigerator, it is worth checking a few more points.

  • Traces of burning or melting of wires and connectors are visible. Such a device is subject to unconditional replacement.
  • The attachment of the device weakened. In this case, mobile contact groups can jam. In this case, the motor begins to vibrate. Should be tightened or replaced by mounting elements.
  • The connectors were ill. Contacts should be cleaned and squeezed.

If in the course of independent diagnostics and repairs it was not possible to achieve success, one should not try to disassemble the refrigerator nodes, especially the motor-compressor. It is better to contact the service center.

Types of launcher relay

Despite the variety of external performance, in modern refrigerators, two main types of launch protection relay are used:

  • Current. Work upon reaching a certain value of the current current. A normally working motor consumes a given current. When overheating of the engine, the current consumed increases sharply, the device works and breaks the circuit, turning off the engine. After cooling the motor, the device resumes its operation.
  • Tokovo-heat. Trigger both when the current value is reached, and when the given temperature is reached. While the engine consumes a normal current, the spiral through which it passes is subject to slight heating and does not affect the bimetallic plate. The higher the current current, the more he heats the spiral. It heats the sensitive plate, it changes its shape so much that it leads to the opening of the contacts through which the electric motor is written.

In the current-heat devices, temperature growth leads to a change in the shape of the bimetallic plate. It is welded from two plates, the metals of which have a different coefficient of thermal expansion. When heated, the bimetallic plate is bending and opens the contact group, turning off the electric motor. After the engine has cooled down, the plate returns to the original form and closes the contact groups, starting the engine again. In addition to the thermal protection circuit, the engine turns on and is also disconnected by the thermostat.

The plate is heated in various ways:

The start.up device also carries out the function of starting the electric motor. To do this, for a short time, a large start.up current is supplied to the engine winding, and after the rotor is folding and starting its rotation, the current is reduced to working values.

Outwardly the device looks like a small box fixed on the compressor casing.

  • Two contacts. phase 220 volts and Earth. Used on synchronous electric motors.
  • Three contacts: launch winding, working winding and earth. Such designs are used on asynchronous electric motors.

Contacts are distinguished by the color of the cables passing to them.

Induction relay of the DHR type are fixed on the refrigerator frame and designed to control the motor-compressors such as DHM. A strong permanent magnet is placed to increase the speed and disconnecting of the engine next to the plate. When the plate, curving under the influence of heat, enters the magnet attraction zone, it attracts it, accelerating the operation. The attraction of the magnet also gives extra time to cool the overheated motor. The cooled plate overcomes the attraction of the magnet and closes the contacts.

RTP type relay has a lower operation current and lower dimensions. It does not require fixing on the frame and is mounted directly on the wires.

You can check the serviceability of a launcher relay by an ohmmeter, multimeter or other available measuring device. The working device has zero resistance between contacts. If the resistance is endless. the device is faulty and it must be changed.

The start.up device works in a single electrical circuit with a thermostat.

The refrigerator user manual indicates which devices can be used for each specific model. This allows you to choose a suitable replacement device, if exactly the same as failed, will be inaccessible.

Before any repair work, you need to make sure that the equipment is not connected to electricity. Otherwise, there is a probability of severe electric shock. RTP.type launch vehicles are easily removed. just disconnect the contacts. When the equipment is not new, the contacts are often oxidized and can be boiled. In this situation, they are toned in the connector with a flat thin screwdriver, loosened and then slightly shifted the connector until the final disconnection of the contact plate.

To remove the part from the refrigerator, the installation method is first determined. on:

First of all, disconnect the connectors, after which the fasteners are unscrewed. If rivets are used, they are drilled at small revolutions of screwdrivers or drills. Experts recommend fixing a new part on the screws.

After disconnecting the contacts, it is necessary to march the wires. In particular, if it concerns the old technique in which the wires darken over time and change their shade. With the help of a flat screwdriver, the latches are squeezed until the relay is disconnected. It is important to do everything carefully, since the plastic latches are fragile.

Replacing relay in models Minsk and Atlant

Such stamps of refrigerators are produced by one plant, so they have a similar device. To remove the relay on the technique of Minsk and Atlant, it is carried out as follows:

It is checked that the device is disconnected from the network;

The wire clamp, which holds the relay, is carefully removed, as well as contacts;

The screws that are attached to the body of the relay engine are unscrewed;

The wire clamp is squeezed and the device is removed.

The installation of a new part is carried out as follows:

the relay is installed on the body of the compressor engine;

The wires join. the previously made marking will help;

The wire clip returns to the place.

The algorithm for checking the starting relay of the refrigerator

With a malfunction of the contact, there will be no. Where there is no contact, there is the cause of the malfunction. However, the launch relay of the RTK-X and LS-08B has a feature: two pairs of cantacts. In case of violation of one circuit in a non.working position, it can be closed through the bar of the contactator, which conducts current. Therefore, a visual inspection is also needed.

First of all, non.working contacts should be cleaned with the smallest skin and rinse with alcohol. In the RTP-1 relay, you may have to bend the bar with a motionless contact in order to ensure dense contact. Now everything should work.

The refrigerator does not start still? Perhaps you need to buy a new relay. And maybe it’s not in the relay, but in the compressor itself. To exclude extra expenses, you need to check the compressor itself.

Fridge freezer refrigerator compressor testing and inspection troubleshooting fault finding

For verification, you will need a simple device of two.wire wire, plug, lining.type buttons, three clamps of the crocodile type. With it, you will launch a motor-compressor without a starting relay, but with protection against overheating of the winding. You can start in the following way.

The algorithm for checking the motor-compressor

If the refrigerator has started without problems, then the malfunction lies in the starting relay. If not, the problem is in the compressor, and the relay can continue to work. Regardless of whether you will repair the refrigerator yourself or call the masters, you can always order the necessary spare parts for the refrigerator in Alm-Zapchasti. The part will cost cheaper, and you will receive a warranty on the product. But the most important thing is that after a successful repair, your refrigerator will be launched on the first attempt and when you need!

A three.phase engine The presence of a launch winding excess element. Consuming 380 volts, it is cut directly to the network, the coils of the stator are pahase. It is required to launch 230 volts from the network. craftsmen begin to chemize. Schemes of stars appear, a triangle using a capacitor that provides a voltage shift of 90 degrees in an arbitrary winding relative to the two remaining. The first plays the role of launching, the capacitor should be disconnected when the engine gains momentum. In fact, from a three.phase motor is obtained two.phase. Of course, you can make a power supply that issues three sinusoids, shifted 120 degrees relative to each other artificially. The start.up relay of the refrigerator echoes the principles of asynchronous engines, serves the implementation of the functions laid down by the name.

Beko CSK 38000 refrigerator malfunctions

A separate Beko two.door refrigerator with the bottom of the freezer is equipped with a drip defrosting of the upper chamber. The freezer is freed from ice manually. The temperature control in the refrigerator is electromechanical.

The following nodes are problematic in the device:

Freon tubes are used steel. The contour wound in the doorway is gradually corroded by a refrigerant, rusts, after 5-7 years a replacement of the contour will be required due to the leakage of the freon.

The condenser grille on the case outside is gradually clogged, the conditional passage decreases. If it is not washed with a frequency of 5-7 years, the performance of the unit will fall, the load on the compressor will increase, the formation of traffic jams in the capillary tube will be provoked. This can lead to expensive repair or replacement of the compressor.

The electromechanical temperature sensor by the manufacturer is programmed for 5 years of work. If a malfunction occurs in the chambers, the compressor works for wear or does not turn on. You can eliminate the malfunction by replacing the device.

The mode in the chambers can be disturbed when the freon leakage. Sign. an ice fur coat appeared in the refrigerator and the temperature rose, and everything is in order in the freezer. With normal mode, in the refrigerator and the melted freezer, it is necessary to check and replace the control board.

There are a lot of reasons for the poor work of the refrigerator, signs of malfunctions differ in some nuances. Accurate diagnostics and repair should be entrusted to specialists.

Factograms of the refrigerators of the Beko CN328220 refrigerator

In the refrigerators Beko with electronic control, self.diagnosis is provided. The system finds deviations in the mode and informs the coded signal in which place the failure occurred.

Look at the Beko refrigerator, the center is the exclamation mark. In case of violation of the temperature regime, it burns, warning about the danger. In all cases, it signals that in one or two chambers the cooling process is disturbed. You decide how relevant it is. If fresh products have just been loaded into the camera, or the refrigerator was disconnected, it will take time to cool.

When the sign “Attention!”It occurs suddenly, he informs of the failure in the system:

In addition, malfunctions on the display can clarify the problem with a flashing number. So, flashing 2 speaks of problems in the cooling circuit. Flashing 3 speaks of faulty heaters, 4. non.content in the sensors system, break or violation of contacts, signal 7. compressor malfunction. When highlighting the letter E in any combination, you should immediately contact the service service. All icons and error codes are set out in the instructions for the operating refrigerator Beko.

About the author

| Denial of responsibility | Contacts |RSS