Solid fuel boiler control unit

And yet most people are discouraged by maintenance of solid fuel boilers, which should produce every 3-4 hours. Due to the fact that the fuel burns quickly, it is necessary to add coal or wood to the furnace regularly. Cleaning the ash pan is also time consuming and not the most pleasant process. And the temperature regulation is the whole problem: to do this, the owner must adjust the position of the flap, which controls the flow of air masses into the furnace.

Now, thanks to the automation, all these processes can be performed less frequently or remotely, while saving money on electricity and gas.

Assembly and adjustment

The process of installing an automatic control system includes:

  • Connecting the blower. As a rule, the turbine is placed on the lowest door of the boiler, where the damper is located. But there are models of units where it is installed on the side wall, or in a special place on top of the boiler, it all depends on the design features. Everything is simple: remove the damper and in its place put the fan, for mounting use four screws. If there are no holes for mounting, they must be drilled. For fans with a damper, installation is done in such a way that when the damper is off, it is closed.
  • Controller installation. First of all, you need to determine the place where the device will be installed. The main requirement is that it must not get hot. On models without a stove hob, the control box must be mounted on top. If the design of the unit allows it, the unit can be mounted on the side wall. Do not forget about the length of cables.
  • Connecting the temperature sensor. Properly installed temperature sensor will ensure the proper functioning of the entire control unit. If the model has no special place for the sensor (hole parameters: diameter of 10 mm, and depth of 60 mm), it can be mounted on the metal outlet pipe. Clamping material is used as fixing element and can be supplied with the unit.
  • Connector connection. To do this, it is necessary to connect the turbine connector with the control unit connector. To finish, connect the mains cable of the appliance. Automation is ready to execute its functions.

Automatics for solid fuel boiler

Temperature range. 5.90 C Temperature sensor resistance10.120 C Power supply. 230 В.

Body: DZR brass Gate: DZR brass Lid: Forton Handle: POM Sealing rings:.

Body: DZR brass Gate: DZR brass Lid: Forton Handle: POM O-rings O-rings:.

Adjustable temperature range: 32 C. 10. 32 C Dimensions. 76 x 76 x 34 mm Degree of protection. IP30 Voltage and frequency.

Motor type. EM 3030 Mains voltage. 230V/50Hz Maximum static pressure. 160 Pa Volumetric.

Country of manufacture. Poland Type of motor. M2E 068-BF Mains voltage. 230V/50Hz Maximum.

Motor type. R2E 150 Mains voltage. 230V/50Hz Maximum static pressure. 285 Pa Volume.

Motor type. R2E 180 Mains voltage. 230V/50Hz Maximum static pressure. 520 Pa Volume.

Engine type. M2E 068-CF Mains voltage. 230V/50Hz Maximum static pressure. 320 Pa Volumetric.

Model. WWK 180 /60W Motor type. SEN80-2/30. B10/AE24 Mains voltage. 230V/50Hz Pressure.

Model. WWK 180 /75W Motor type. SEN80-2/40.B10/AE47.

Heating medium temperature. 55. 63 C Designation. Thermostatic mixing valves Material

Temperature setting range. 61 C Purpose. Check valves Material. brass Temperature.

Heating medium temperature. 55. 63 C Purpose. Thermostatic mixing valves Material

Adjustable temperature range. 61 C Purpose. Non return valves Material. brass Temperature.

Model No. 10348 Opening temperature. 55 C Connection thread. G 1″ female.

Model No. 10348 Opening temperature. 55 C Connection Thread. G 1″ female.

Model No. 11807 Opening temperature. 55 C Connection thread. G 1 1/4″ female.

Model No. 10348 Opening temperature. 55 C Connection thread. G 1 1/2″ female.

Model No. 10348 Opening temperature. 55 C Connection thread. G 1 1/2″ female.

Model No. 10348 Opening temperature. 55 C Connection thread. G 2″ female.

Model No. 10348 Opening temperature. 55 C Connection thread. G 2″ female.

Designation. Thermostatic control valves Actuator connection thread. M28x1.5 Material.

Destination. Thermostatic control valves Actuator connection thread. M28x1.5 Material.

Purpose. Thermostatic control valves Actuator connection thread. M28x1.5 Material.

Today solid fuel boilers are again in demand. All because manufacturers began to use in the production of such heating systems automation, which gives such boilers many advantages. Among them:

autonomy of heating system and more.

over, today boilers of this type are used not only in households, but also in large industrial enterprises.

As for automation for solid fuel boilers, the main components are:

controller module control and system settings;

blower blower turbine, which controls the flow of air into the boiler chamber.

If you need to buy automatics for solid fuel boilers, contact our company. We offer products from leading manufacturers.

Automatics for solid fuel boilers | How to choose and what is different

In the Ukrainian market of heating equipment solid fuel boilers are in demand now more than ever. Though they are a bit inferior to gas and electric analogues in functionality, but they are much superior due to availability and relatively low cost of fuel. The automation for the solid fuel boiler allows reaching the maximum performance of the equipment. It makes it possible to optimize the combustion process and increase its efficiency by 20-30% on average. The originally programmed boiler can operate with little or no human intervention, ensuring comfort and complete safety to the user.

Air

Compact automatic control unit for solid fuel boilers. Allows installation and control of a powerful circulating pump and fan with an appropriate current load of 2 and 1 amp; modifications allow load currents up to 5A.

  • Manufacturer: Poland;
  • Power supply: 220V/50Hz;
  • Capacity of the pump to be connected: up to 200 W;
  • Fan output: up to 200 W;
  • Setting the temperature of the coolant: 30-80oS;
  • Temperature accuracy: 1oC;
  • Range of setting the room temperature: 20-45oC;
  • Manual target temperature setting and circulation pump control.
  • Approximate cost: 6500-7250

A functional control unit with a practical casing that is protected against overheating. User-friendly interface. The LCD display and a wide range of operating keys allow easy adjustment of the automation and boiler control.

Purpose

Control unit is an excellent way to automate the operation of solid fuel boiler. It keeps the system temperature stable, independent of external factors. that is its main advantage.

As a result, there is an opportunity for fuel to burn completely and at the same time to give the heat to the full extent. Reduces fuel consumption and increases the time between putting it into the combustion chamber.

The controller works in conjunction with a fan. As a result of joint work the following is provided:

  • The set temperature of the heating medium in the heating circuit is maintained;
  • Increases the efficiency of the boiler;
  • High efficiency with different fuel quality.

The temperature of the coolant is monitored with a special sensor.

Connection diagram of solid fuel boiler control unit

Boiler control units

Temperature range. 5.90 C Temperature sensor resistance10.120 C Power supply. 230 В.

Power. 230V/50Hz/-10% Maximum power consumption. 4 W Ambient temperature. 5-50 o C.

Power. 230V/50Hz /10% Power consumption. 4 W Ambient temperature. 10.50 C Load.

Power supply. 230V/50Hz /-10% Power consumption. 5 W Ambient temperature. 5.50 C.

Power supply. 230V/50Hz /-10% Power consumption. 5 W Ambient temperature. 5-50 C Circulation pump load.

Country manufacturer. Poland Hysteresis. 1 C Maximum fan power. 150 W Maximum power.

Power supply. 230/50Hz/-10% Power consumption. 2W Output load of central heating and ventilation pump 6A Measuring range.

Country of manufacturer: Poland Functions: Controls fan, CH pump Boiler temperature 25-90 C CH pump on temperature.

Country of manufacturer: Poland Functions: Fan control, CH pump Boiler temperature 25-90 C CH pump switching temperature.

Твердотопливный котел 25 квт. Solid-fuel boiler 25 kW

Power. 230/50Hz/-10% Power Consumption. 2W Output load of central heating pump and vent 6A Measuring range.

Country of manufacturer: Poland Heating temperature control range: 2585 C Hot water temperature control range.

Measuring range of temperature. 0C. 110C Temperature control range C.O 20C. 80C.

Country of manufacturer: Poland Heating temperature regulation range: 2585 C Hot water regulation range.

Country of manufacturer. Poland Hysteresis. 1 C Maximum fan output. 250W Maximum power.

Mains voltage. 230 V / 50 Hz Power of circulation pump. up to 130W Power of air supply fan. up to 130W Range.

Mains voltage. 230 V / 50 Hz Power of circulation pump. Up to 200 W Air delivery fan power. up to 200 W.

Thermostat type: wired, non-programmable Temperature display: 0C. 39.5C (0.5C/step) Measurement accuracy.

Country of manufacturer. Poland Hysteresis. 1 C Maximum fan power. 550 W Maximum.

Power supply. 230V/50Hz /-10% Power consumption. 7 W ambient temperature. 5-50 C Output Load.

Power. 9V DC Maximum current consumption. 100 Ma Transmission. IEEE 802.3 10Mbit/s Network.

Pump control. 1 pc Flue gas sensor. no Thermostat output. No Remote control. no.

Power. 230V/50Hz/-10% Maximum power consumption. 4 W Ambient temperature. 5-50 o C.

Power supply voltage. 230V/50Hz/-10% Power consumption. 2W Ambient temperature. medium. 10-50 C Output load for.

Boiler control units are necessary for the user to ensure safe and smooth operation of the heating system. However, optimum performance depends directly on the correct choice of automation, which is used to control the entire system.

Our online store offers you controllers. which allow for efficient, uninterrupted and economical operation of the heating system. And it is achieved due to the fact that the controller regulates the work of the fan and circulation pump, maintains the set temperature readings. As a result you get the desired temperature regime without constant control of the boiler from your side.

Realizations of solid fuel boilers with automation

Automation is available for all types of boilers: classic, pyrolytic and slow-burning.

From simple mechanical systems to the most advanced: electronic systems with remote control and monitoring via the Internet.

Any automatic electronic system for heating boilers consists of sensors (temperature, pressure, draft, flame), actuators and controller that controls these devices according to a predetermined program and readings from sensors.

Slide gate control

The slide gate is installed in any solid fuel boiler at the outlet of the furnace in front of the chimney and is used to control the draft and exhaust velocity of gases produced during fuel combustion.

Proper adjustment of the slide gate significantly increases the efficiency of the boiler, and in its absence most of the useful energy will simply fly out into the chimney. And this causes increased wear of the boiler and chimney from overheating.

solid, fuel, boiler, control

Electromagnetically operated butterfly valve for automatic solid fuel boiler, increases its efficiency.

The gate valve drive can be either electromagnetic, providing two positions (fully open, half-open) or motorized, which allows more accurate control of the chimney cross-section.

Temperature sensor is installed in the boiler jacket. When the temperature of the heating medium rises, the automatics closes the damper, reducing the draught and reducing the boiler output, when the temperature drops, on the contrary, it opens the damper and increases the output.

Fans

Another way to control the draught is to use a blower for forced air circulation in the boiler. It is borrowed from industrial units, where because of the volume of fuel efficiency plays an important role.

Blower WPA X2 for solid fuel cell boilers.

There are two types of fans for boilers of long combustion:

  • Blower is placed in front of the furnace instead of the ash door and affects the supply of oxygen into the furnace, thus regulating the intensity of combustion.
  • The flue gas aspirator is placed either at the beginning of the chimney (immediately after the boiler) or at its end.

The main task is to adjust the draught and its amplification, when the natural draught is insufficient for efficient operation of the boiler (due to weather conditions or the chimney construction).

The speed of the fans and thus their influence on the system draught can be steplessly varied over a wide range by means of a thyristor control unit.

Note ! In case of insufficient temperature of the heat carrier, the controller increases the draught, changing the fan speed. If the boiler is too hot, the draft decreases.

Ash door

The most common variant of automatization is adjusting of ash door opening. Opening or closing the door changes the natural draught and influences the temperature of the boiler.

The simplest ashtray door thermo-mechanical control systems. Device consists of a thermosensitive liquid, a spring and a chain for connection to the door. Installed in standard boiler openings, where thermal contact with the coolant is ensured.

Adjustable ash door of solid fuel boiler as one of the automation options.

The desired temperature is set on the thermoregulator. When the temperature becomes too high, the fluid expands, overcomes the spring force and loosens the circuit, the flap closes, the draft decreases and the temperature falls. Otherwise, the door opens wider and the temperature rises.

Important! Similar systems require no power and are reliable, but regulation accuracy is limited to 510 C.

Electronic systems use temperature sensors to control the coolant and electromechanical actuators installed on the ash door. Work similarly, with up to 1 C accuracy.

Since electronic systems require constant power, it is worth taking care to install an uninterruptible power supply (UPS) so that in the event of a power outage the boiler will not fail.

Connection of automatics to the solid fuel boiler

The installation process begins with the fan, which is installed on the air or ash door. Many modern solid fuel models already have spaces and holes for attaching a supercharger. Otherwise it is necessary to drill the holes yourself and fix the blower with four bolts.

Pay attention to the thermal gasket: it is obligatory, but not on all models of fans. As a result the turbine should be installed according to the photo below.

Properly installed blower fan.

The second step is the installation and connection of the automatics itself to the solid fuel boiler. The controller is installed on top or on the side of the case through the holes designed for this device. Although many controllers are made of heat-resistant materials, it is advisable to install the device on the coldest part of the boiler, if necessary, put a heat-resistant gasket of incombustible material.

It remains only to connect all elements and connect the controller to the power supply. A detailed connection diagram is always specified in the instructions of the automatics, for example, this looks like the connection diagram to the control unit Komfort ECO:

Connection diagram of automatics by the example of Komfort Eco.

How you make the setting

The detailed tuning algorithm also depends on the model and is always described in the manual. In general, this is the procedure for tuning:

  • Setting the switching temperature of the circulation pump. allows to switch on the pump not immediately, but when the coolant has already warmed up, necessary to prevent condensation (usually set at 50°C).
  • Setting the desired heating circuit or room temperature, depending on the model and controls.
  • Setting the fan speed (1 to 10) or selecting one of the automatic modes for fan speed control. When setting the supercharger completely manually, you also need to set the parameters of the fan run time and frequency of its activation in the combustion support mode.
  • Fueling and ignition of the boiler. Control of its operation and, if necessary, adjustment of the parameters.
solid, fuel, boiler, control

In some models you can also program the work for the day or week ahead, set the temperature threshold after which the fan begins to slowly reduce the speed, etc.д.