Split system gives an error Fe
Beko air conditioning errors of the BKC Inv, BKL Inv series
E1. Error of the inner temperature sensor
E2. Evaporator sensor error
E3. Engine error
E5. Switching error between the internal and external block
1e is an external temperature sensor error
2e. Condenser sensor error
F3 FF03. High condensation temperature in cooling mode
F4 FF04. High Tempelers of condensation in heating mode
F6 FF06. Incorrect operation of the engine fan engine
F7 FF07. Error of the sensor of internal air temperature
F8 FF08. Malfunction of the temperature sensor of the evaporator
F9 FF09. Capacitor temperature sensor malfunction
Daikin air conditioners error codes
E0 has worked as a protective device (general), where
E-classification code, 0-depth code.

A0 worked protective device (general)
A1.Proceed of the printed circuit board of the internal unit
A2.Blocking the fan motor
A3.Anomalous level of drainage
A4.The heat exchanger malfunction (temperature)
A5.Anomalous temperature of the heat exchanger
A6.Overloading the fan engine
A7.Falf in the drive of the blinds
A8.General current overload
A9.Electronic expansion defect
AA. Overheating of the heater
AH. Air filter is polluted
Aj. Incorrect performance setting (internal block)
AE. Insufficient water supply
C0.Sensor malfunction (general)
C3.Drainage level sensor defect
C4.Failure of the heat exchanger temperature sensor 1
C5.Failure of the heat exchanger temperature sensor 2
C6.Fan engine overload, sensor blocking
C7.Falfestable sensor of the blinds drive
C8.The input current sensor is faulty
C9.The termistor of the input air is faulty
CA. Faulty the termistor of the output air
Ch. The sensor of pollution worked
CC. Humidity sensor is faulty
CJ. The temperature sensor on the control panel is faulty
CE. Malfunction of the radiation sensor
Amstrad split inverter AC F6 error code ko kaise solution Karen in Hindi video ok koi baat nahin
CF. High pressure sensor failure
E0.The protective device (general) worked
E1.Outdoor unit malfunction
E3.High.Pressure sensor worked (HPS)
E4.Low pressure sensor worked (LPS)
E5.Overloading the compressor motor, overheating relay
E6.Blocking the compressor engine for current excess
E7.Blocking the fan motor for excess current
E8.General current overload
E9.Electronic expansion valve malfunction
AH.Current blocking of the pump
EC.Anomalous water temperature
EJ.An additional protective device worked
Ee.The abnormal water level in the drainage system
EF.Heat accumulation block is faulty
H0.Sensor malfunction (general)
H1.The air temperature sensor is faulty
H2.The malfunction of the system of electric power supply system
Mitsubishi split air conditioner error code
H3.High pressure sensor malfunction
H4.Low pressure sensor malfunction
H5.The compressor does not work. The overload sensor worked.
H6.The lock sensor worked. Compressor overload
H7.The lock sensor worked.Religion of the fan.
H8.The input voltage sensor worked.
H9.The outdoor air temperature sensor.
Ha.The output sensor worked
HH.The water pump lock sensor worked
HC.The sensor for hot water worked.
He.The drainage level sensor worked
HF.Close of heat accumulation unit
F0.Protective devices worked and
F1.The protective device of the system worked
F2.The protective device of the system worked
F3.High temperature of the injection pipe
F6.Anomalous temperature of the heat exchanger
FA. Unacceptable injection pressure
FH.High oil temperature
FC.Inadmissible absorption pressure
Fe.Unacceptable oil pressure
FF.Unacceptable oil level
J0.The fault of the termistor
J1.Pressure sensor malfunction (general)
J2.The current sensor is faulty

J3.Malfunction of the temperature sensor of the injection pipe
J4.Sensor malfunction at the low pressure saturation point
J5.The terms of thermistor on the suction pipe
J6.The fault of thermistor on the heat exchanger (1)
J7.The terms of thermistor for the heat exchanger (2)
Kentatsu air conditioning errors
The company’s managers will answer all your questions, select the necessary equipment and prepare a commercial offer.
P4. Prevention protection
P5. Capacitor temperature protection
P7. The injection temperature is too high, the compressor protection is enabled
P9. Too low outdoor temperature, with an increase, the protection will turn off automatically
P10. Output protection
P11. Suction protection protection
P12.Current overload protection
E1. T1 internal air temperature sensor is closed/torn
E2. The temperature sensor of the evaporator T2 is closed/torn
E3. T3 capacitor temperature sensor is closed/torn
E4. The outdoor temperature sensor is closed T4 is closed/torn
E5. The connection between internal and external blocks is violated
E6. Protection of the external unit
E10. Compressor absorption error
E13. Compressor phase error
E14. Incorrect phasing of the compressor
HS. Starting defrosting
Detailed information on errors and methods for their elimination in the manual service.
E1. EEPROM error (energy.Dependent memory on the board)
E2. Error over the zero (Zero Crossing Error)
E3. Anomalous fan speed
E4. The compressor current protection worked 4 times
E5. The temperature sensor of the internal air is closed/torn
E6. The temperature sensor of the evaporator is closed/torn
P4. Thermal protection of the evaporator of the internal unit
P5. Thermal protection of the capacitor of the external unit
P9. Protecting the defrosting function or creating a comfortable air flow
E1. Cliff or short circuit of the T1 temperature sensors circuit
E2. The temperature sensor of the evaporator T2 is closed/torn
E3. T3 capacitor temperature sensor is closed/torn
E6. Protection of the external unit
E0. Faulty sensor at room temperature
E1. Faulty temperature sensor of the evaporator
E2. The temperature sensor of the outer unit is faulty
E3. The external block is faulty
E4. The temperature sensor of the drainage pump is faulty
E5. Eeprom error
E6. Increased water level
Determining errors on LED indicators on the air conditioner panel.
E2. A room temperature sensor malfunction.
E3. Malfunction of the temperature sensor of the evaporator.
E4. Failure of the temperature sensor of the outer unit.
E6. Failure of the outer unit (see. Indicators on the control of the external unit).
E8.Exceeding the water level.
The company’s managers will answer all your questions, select the necessary equipment and prepare a commercial offer.
The company’s managers will answer all your questions, select the necessary equipment and prepare a commercial offer.
Classification of air conditioning errors
Codes of faults of air conditioners are classified according to the generally accepted system combining system and consist of 2-3 or more signs. It can only be numbers or letters of the Latin alphabet, as well as a combination of letters and 1-2 digits.
The letter symbols determine the place where the failure occurred, and by the number or number of diode blinking, you can determine what kind of breakdown occurred.
Classification of error codes:
The owner of the device does not need to memorize all the characters and codes of air conditioning errors, especially since in each brand of equipment they are different. It is enough to pay attention to the problem in time and disable the device from the network until the reasons for the cause of failure.
In the instructions for the operation of air conditioners, information about codes is published, which will allow the owner to determine the type and complexity of the breakdown. If the problem of malfunction cannot be solved independently, you will have to call the master from the service center.
Symbol codes of air conditioning errors
Symbol codes are presented in the form of several signs, for example “”. You can understand the error in this case not by the symbol itself, but by their number. As a rule, symbolic errors are displayed on the control panel.
Two.Digit conditioner error codes
In two.Digit errors, Latin letters and numbers are used. The first part of the code displayed by letters is responsible for the structural components of the split system.
Transcription of characters (briefly):
- “A” and “B”. Malfunctions of the inner block;
- “E”, “H”, “F”, “j”, “l”, “p”. Problems arose in the external block;
- “U” and “m”. These codes signal the problems of the system.
The second error code is presented from the numbers in the sequence from 0 to 9. To determine the exact cause of the problem, it is recommended to study the user instructions that are included in the air conditioner.
Three.Digit conditioner error codes
In 3-digit error codes, letters and numbers are used, more often in a combination of one letter symbol and two digits. The attaching instructions have a detailed transcript.
Dantex air conditioners and chillers error codes
E1. An error has arisen in energy.Dependent memory; E2. An error of transition through zero arose; E3. There is no control of the speed of the fan of the internal unit; E4. The regime of protection against an increased voltage level applies; E5. There is no contact with the control of an open temperature sensor; E6. There is no contact with the control of the temperature sensor of the evaporator.
E0. An error has occurred in the water flow meter; E1. An error occurred when connecting phases; E2. A communication error arose; E3. An error of the temperature sensor of water at the output arose; E4. There was an error of the temperature sensor of water at the output of the peeling heat exchanger; E5. Error in the operation of capacitor A; E6. Error in the operation of capacitor B; E7. An error arose in the temperature sensor of the outer air; E8. An error arose in the temperature sensor of the pumped air; E9. An error in the flow meter arose; EA. The main block revealed a decrease in the number of additional blocks; Ev. Malfunctions in the work of the protection system from freezing; EU. Malfunctions in the work of a drive controller; ED. There was an error in the control system and communication between the blocks; ED. Operation of electrical protection; Its. An error arose in connection between the microprocessor and the control panel;EF. An error of the temperature sensor of water at the entrance arose; RO. Overheating or increased pressure; P1. The pressure in system A decreased; P2. Pressure increased or air overheated in system B; P3. The pressure in the system decreased; P4. There was an overload on the current in the system A; P5. There was an overload on current in the system B; P6. Increased pressure in the capacitor of the system A; P7. Increased pressure in the condenser of system B; P8. Malfunctions in the operation of the temperature sensor of the compressor discharge in the system A; PB. Freezing protection; Re. The temperature in the heat exchanger decreased; F1. Errors in the work of constant memory; F2. Errors in the work of wired controllers.
Contact our company and we will help in solving your problem! Call the phone number 7 (495) 151-09-99, or write to Order@cc-online by

Air conditioning errors
Control of the fan and the main control board have no connection between themselves.
LG Art Cool air conditioners error codes and all other LG air conditioners:
CH1 or C1. A short circuit of the inner air temperature sensor or a break in a chain occurred;
CH2 or C2. A short circuit of the temperature sensor of the evaporator or a break in a chain occurred;
CH4 or C4. A short circuit of the temperature sensor of the capacitor or a break in a circuit occurred;
CH5 or C5. Internal and external blocks are connected;
CH6 or C6. In the inverter module, the current is exceeded;
CH8 or C8. Lack of rotation of the fan of the internal unit;
CH9 or C9. Lack of rotation of the fan of the external unit;
CH-10 or C10-the thermoresistor of the temperature control of the compressor of the split system is faulty (there was a short circuit or cliff);
CA. The cluster temperature exceeds 130 degrees Celsius;
CC. Eeprom error (internal energy.Dependent memory) occurred;
CD. There was an error in the inverter module;
PO. There is no error, finding the system in energy saving mode;
LO. There is no error, finding the system in testing mode.
Calling Master 8 (495) 565-38-25 and 8 (499) 409-84-95. Or an online application
E0 is the operation of a common protective device, where it is a classification code, and 0 means a detailed code
A0. The general protective device worked
A1. The printed circuit board of the internal unit is faulty
A3. Unacceptable level in the drainage system
A9. Electronic expansion valve is faulty
AH. There was a clogging of the air filter
Aj. Productivity is incorrectly exhibited (internal block)
C4. The temperature sensor of the heat exchanger 1 is defective
C5. The temperature sensor of the heat exchanger 2 is faulty
C6. The fan engine is overloaded, the sensor is blocked
C7. Lyluzi drive sensor failed
C8. The input current sensor failed
C9. Breakdown of the thermistor of the input air
CA. Breakdown of the termistor of the output air
CJ. Temperature sensor does not work on the remote control
CF. High.Pressure sensor failed
Calling Master 8 (495) 565-38-25 and 8 (499) 409-84-95. Or an online application
E0. The general protective device worked
E1. The printed circuit board of the external unit is faulty
E3. HPS works (high.Pressure sensor)
E4. LPS works (low pressure sensor)
E5. The compressor motor is overloaded, the relay of overheating worked
E6. The compressor engine is locked in excess of current
E7. The fan motor is locked in excess of current
E9. Electronic expansion valve is faulty
EJ. An additional protection device worked
EE. A critical water level in the drainage system
EF. Damage to the heat accumulation unit
H1. Air temperature sensor is faulty
H2. Electric power supply system malfunctioning
H3. High pressure sensor is faulty
H4. Low pressure sensor is faulty
H6. Overload of the compressor, the system is blocked
H7. Overload of the fan, the system is blocked
H9. Anomalous input temperature
Ha. Abnormal temperature of the output air
He is the signal of the sensor sensor of the drainage system
HF. Heat accumulation unit above
F0. Protective system devices operate and
F1. A protective system device operates
F2. A protective system device operates
F3. Abnormally high temperature of the bump pipe
F6. Unacceptable temperature in the heat exchanger
Fa. Unacceptable pressure of the pumped air
Calling Master 8 (495) 565-38-25 and 8 (499) 409-84-95. Or an online application
FC. Unacceptable pressure of absorbed air
Fe is an unacceptable oil pressure indicator
FF is an unacceptable oil level
J1. General malfunction of the pressure sensor
J3. Damage to the temperature sensor of the air pipe
J4. The sensor is not working at the low pressure saturation point
J5. Thermistor is faulty on a suction pipe
J6. Thermistor is faulty on the heat exchanger (1)
J7. Thermistor is faulty on the heat exchanger (2)
J8. Thermistor is faulty on the liquid pipe
J9. Thermistor is faulty on a gas pipe
Jh. Temperature sensor is faulty
JC. The absorption pressure sensor is faulty
L3. The control temperature of the control is increased
L4. The temperature of the radiator of the power transistor is increased
L5. Short.Term overload of direct current at the output
L6. Short.Term overload of alternating current at the output
L8. Delayed electronic thermal relay
LC. Broadcasting with an inverter in the outer block
P0. Gas lack (due to icing equipment of the heat accumulation system)
P1. There is no phase, power supply in imbalance
P4. Failed the power transistor (radiator temperature sensor)
P5. DC sensor is faulty
P6. The permanent/variable current sensor is faulty
P7. Input current (in the multisystem) increased
Pj. External block, performance is incorrectly exhibited
Calling Master 8 (495) 565-38-25 and 8 (499) 409-84-95. Or an online application
U0. Reduced pressure in the system due to lack of gas
U1. The phases are incorrectly connected (it is necessary to change the phases)
U2. Low voltage in the power source
U4. Communication failure between external and internal blocks
U5. Communication failure between the remote control and the internal block
U6. Communication failure between the main and subordinate internal blocks
U7. Communication failure between the battery or outer blocks
U8. The connection between the control panels is broken
Ua. The parameters of the external unit are incorrectly exhibited
Uh. The address (external/internal block) has not been introduced)
Error codes
All air conditioners equipped with a self.Diagnosis system and determination of malfunctions, in case of malfunction, issue an error code. In turn, some “repairmen” have only one goal. To earn as much as possible on your misfortune. In this regard, I recommend that everyone preserve this material from which you will learn how to identify the problem of the error code. Knowing the reason for the problem, believe me, you can save considerable funds, and perhaps even eliminate it with your own hands.
Codes of air conditioners’ errors on brands of error codes LG / Elji
A short circuit of the temperature sensor of air or a break in a circuit occurred;
A short circuit of the temperature sensor of the evaporator or a break in a chain occurred;
Poor connection between the control panel and the wired internal unit;
Error of the float sensor of the level of condensate or pump (drainage pump);
Error of connection of the external with the inner block;
There was a short circuit of the temperature sensor of the outer unit or a break in the circuit;
Inclusion of the internal blocks of the multisystem in different working modes;
HL. A mistake like 04, the float sensor is open;
CL. The children’s lock is installed, to turn on, click Timer Min Buttons 3 seconds;
PO. Jet Cool mode is installed, you should press the Jet Cool button to exit
DC has a voltage below 140 V (voltage after the transformation module, not power);
Error on low/high pressure, pressure sensors are open;
The supply voltage below/above the normal indicator;
The PSC error (inductance coil, reactor) occurred;
The injection pipe has a high temperature (Inv);
The discharge pipe has a high temperature (cons.);
41-the temperature sensor D-pipe is closed/torn (Inv);
The temperature sensor of the outdoor air closed/broke off;
The capacitor temperature sensor ended/broke off/broke;
The sensor on the suction tube closed/broke off/broke;
48-absence/cliff of D-pipe sensor and temperature air sensor;
Overload by power of the combined type;
52-there was a compound error (Main Micom-Sub Micom);
53-there was an error of connection (external-entry blocks);
Change the phase, irregularities of the phase sequence, for systems with three.Phase nutrition;
EEPROM error (internal energy.Dependent memory);
The condenser tube (condenser) has a high temperature;
The radiator has a high temperature (most likely, we are talking about the radiator of cooling the inverter power module);
The capacitor has a low temperature;
There was a short circuit/breakage of the temperature sensor;
Blocking the external BLDC (DC sub.Collection electric motor) of the fan;
Control of the fan and the main control board have no connection between themselves.
LG Art Cool air conditioners error codes and all other LG air conditioners:
CH1 or C1. A short circuit of the inner air temperature sensor or a break in a chain occurred;
CH2 or C2. A short circuit of the temperature sensor of the evaporator or a break in a chain occurred;
CH4 or C4. A short circuit of the temperature sensor of the capacitor or a break in a circuit occurred;
CH5 or C5. Internal and external blocks are connected;
CH6 or C6. The current exceeded in the inverter module;
CH8 or C8. Lack of rotation of the fan of the internal unit;
CH9 or C9. Lack of rotation of the fan of the external unit;
CH-10 or C10-the thermoresistor of the temperature control of the compressor of the split system is faulty (there was a short circuit or cliff);
CA. The temperature of the bumps exceeds 130 degrees Celsius;
CC. Eeprom error (internal energy.Dependent memory) occurred;
CD. There was an error in the inverter module;
PO. There is no error, finding the system in energy saving mode;
LO. There is no error, finding the system in testing mode.
[curtail] Samsung / samsung air conditioners error codes
E464. Overload of the power module by current
E466. There was an error for the voltage of the DC board module
E221. An error with an outdoor temperature sensor occurred
E251. An error with a temperature sensor occurred
E468. Error of the electric current sensor
E237. Error of the temperature sensor winding
E202. Connection time (1 minute) has expired
E440. Operation Condition Security Low
E441. Operation Condition Security High
E469-There was an error DC-LINK voltage sensor
E472. There was an error of crossing zero voltage zero
E121. The temperature sensor of internal air closed/broke
E122. The temperature sensor of the evaporator closed/broke
E154. There was an error of the fan of the internal unit
E101. Connection time (1 minute) exceeded
Flashing all indicators. EEPROM error (internal energy.Dependent memory)
Daikin air conditioners’ errors / Daikincodes of Hitachi air conditioning errors / Hitachi
Hitachi/Hitachi air conditioners’ errors of the internal unit indicator 301
If the Timer indicator blinks with a frequency of once per second, this indicates the heating of equipment before launch and is not an error.
If the Timer indicator flashes several times and then stops, refer to the list below
01 The temperature of the inner coil is too high for cooling, or too low for the heating mode. Reverse valve refusal from work.
02 forced launch of an external module. It is not a mistake.
03 Merchant of connection. A communication defect between an internal module, external module or central fee.
06 float switch activated. Check the work of the pump and drainage system.
07 should start a pump that pumps condensate manually. The drainage system switched to the test mode, an error of the central board.
08 blinds do not open. Defect in the mechanism of blinds, microswitch or central board (only for RAF models).
Timely repairs of the air conditioner, the key to its long.Term operation!
E0 Violation of the E1 condensate removal function in the compressor increased the E2 heat exchanger of the internal module is covered with ice E3 insufficient pressure in the compressor E4 compressor E5 compressor is disconnected due to increased load E6 no connection between the E7 blocks does not correspond to the internal modulus to the command from the remote control E8 of the internal electric motor The temperature thermal attempt in room F1 turned off the module of the heat exchanger of the heat exchanger of the internal module F2 disconnected the heat exchanger of the external module of the F3, the street thermal attewer F4 disconnected the thermal attemptor on the air supply of the FF, the power supply of electricity is broken
The air conditioner does not work well? Call the number 7 (495) 920 47 96 Order the air conditioning repair now and your air conditioner will last longer!
Model HSU-09 / 12HVA103 / R2 (BD) Model HDU-24CA03 / M (R1) HDU-28CA03 / M (R1) HDU-36CA03 / M (R1) HDU-42CA03 / M (R1)

Haier = e0 indicator Time. Lamp. The compressor works indicate lamps = 10 incorrect air conditioner (old) = drainage system malfunction incorrect air conditioner (new) = drainage system malfunction fault code = e1 indicator time. Lamp. The compressor works indicate the lamps Haier = 1 A Title = incorrect air conditioning Haier (old) = temperature sensor is broken by the wrong air conditioner (new) = temperature sensor is broken by a malfunction code = e2 Haier time indicator. Lamp. The compressor works indicate lamps = 2 irregular air conditioning (old) = closed the coil temperature sensor is broken by the wrong air conditioner (new) = closed sensor of the coil temperature of the broken fault code = e3 indicator time. Lamp. The Haier compressor works indicate lamps = 3 irregular air conditioner (old) = the outer temperature sensor is broken by the wrong air conditioner (new) = the outer temperature sensor is broken by a malfunction code = e4 indicator time. Haier lamp. The compressor works indicate lamps = 4 irregular air conditioner (old) = the outer temperature sensor of the coil is broken. The incorrect air conditioner Haier (new) = Outside temperature sensor of the reel is broken. Code of malfunction = e5 indicator time. Lamp. The compressor works indicate lamps = 5 incorrect air conditioner (old) = for limiting the current current of the conditioner (new) = overload on the protection current of the limit for the haier code of malfunction = e6 indicator time. Lamp. The compressor works indicate lamps = 6 incorrect air conditioning (old) = pressure, the defense of the defense of the air conditioner (new) = pressure) worked protection Haier Code of Furs’ Code = E7 Indicator Time. Lamp. The compressor works indicate the lamps Haier = 7 The wrong air conditioner (old) = the connection of the conflict from the wire remote control and the internal unit. Incorrect air conditioning (new) = Three Phase Protection Code Failed Code = E8 Indicator Time. Lamp. The compressor works Haier indicate lamps = 8 incorrect air conditioning (old) = communication of the problem between the internal and external unit. Incorrect air conditioning (new) = presentation of the problem between the wired remote control and the internal unit malfunction code = e9 indicator time time. Lamp. The Haier compressor works indicate lamps = 9 incorrect air conditioning (old) = three protection phases of the wrong air conditioner (new) = communication of the problem between the internal and external block HSU-09/12hva103/R2 (BD) for Eorope error codes and description of the internal and external display (1) internal and external = e7 are closed by the indication with the indication is closed = closed (LED1 flash of times) = 15 Description = Merciful communication error between the internal and external block Haier internal and external = closed fault = e1 code with an indication is closed = closed (LED1 flash of times) = Description = Haier temperature sensor in the room in the premises of the internal and external = closed fault = E2 code is closed = closed (LED1 flash of times) = Description = heat.Intensified flash. The malfunctions of the Haier sensor internal and external = closed fault = E4 code with the indication is closed = closed (LED1 flash of times) = Description = closed EEPROM error Haier internal and external = E14 Code is closed. Haier fanInternal and external = closed fault = e9 code by the indication is closed = closed (LED1 flash of times) = description = high work E9 intensive protection Haier error codes and description of the internal and external display (2) The index code is closed = F12 time closed (LED1 outbreak of times 1 Description = closed EEPROM error Haier closed failure. Indication code is closed = F11 is closed (LED1 flash of times) = 2 Description = IPM protection is closed. LOVE HAIRO COMPLE COMPLEMENT = F22 closed (LED1 flash of times) = 3 Description of protection against overstrain AC electricity for the external Haier model is closed. The indication code is closed = F11 is closed (LED1 flash of times) = 4 Description = Beneficial error between the IPM and the exterior printing board Haier is closed the Indication Code is closed = closed (LED1 Flash times) = 5 Description = 5 pressure or protectionFrom overheating for the Haier compressor, a malfunction is closed. The indication code is closed = F11 is closed (LED1 flash of times) = 6 Description = Power Haier voltage is too high or low is closed. The indication code is closed = F4 closed (LED1 flash of times) = 8 Description = STRICTION FROM PROTECTIONS for overheating for The temperature of the exhaust gases is closed the malfunction of the indication code is closed = closed (LED1 flash of times) = 9 Description = open malfunction of the Haier fan engine is closed. The indication code is closed = F21 is closed (LED1 flash times) = 10 description = frost to remove the failure sensor is closed by Haier malfunction The indication code is closed = F6 closed (LED1 flash times) = 12 Description = surrounding refusal of the temperature sensor Haier is closed by the indication code is closed = F25 is closed (LED1 flash times) = 13 description = exhaust refusal of the temperature sensor is closedFaulty indication code is closed = closed (LED1 flash of times) = 18 Description = deviate from normal for the compressor. Closure is closed the Haier Code is closed = F11 closed (LED1 flash of times) = 19 Description = The loop of the Error detection station is closed. The indication code is closed =. “” “.Closed (LED1 flash of times) = 24 Description = For the current of the compressor, the malfunction is closed the indication code is closed =-closed (LED1 flash of times) = 25 Description = triggering protection against strain for one-span compressor
Universal repair recommendations
Before starting work, disconnect the air conditioner from the electric network.
Carefully study the instructions attached to the device. This will save time to search for twisting fasteners and plastic latches, holding the external elements of the climate technique body.
When repairing the air conditioner at home, use a tool with electrical insulation. Be careful and careful, do not touch the rotating and livestock details
Remove the sequence of analysis of the inside of the unit on the smartphone. This will help to properly assemble the unit and guarantees that all the details will be in their places. Do not make changes to the operation scheme of the device. To replace, use only original details or analogues approved by the manufacturer.
Do not carry out repairs in a hurry. Highlight this occupation at least 1-2 free hours. Check if the necessary tools are available.
- Slotted (flat) and cross screws of small and medium sizes;
- Kusachki;
- Pliers;
- Multimeter;
- Cleaning wire.
Depending on the model, wrenches and hexagons may be required. If most of the tools are not available, think well whether it is worth starting the repair.
How to independently diagnose the air conditioner. Recommendations for beginner masters:
Haier split system is a complex unit with a large number of additional functions. With clear observance of the rules of operation and timely replacement of consumables, it works for a long time and without failures. The manufacturer gives a branded guarantee for equipment. During its action, it is not recommended to repair the device independently.
When the guarantee has expired, small breakdowns can be eliminated with your own hands, and the restoration of the operability of power units and electronic boards can be entrusted to professionals specializing in the maintenance of climate technology.