BAXI Main Four 240 F: its main features and instructions
Baxi Main Four 240 F gas boiler is a fourth.Generation device. The presented design should be installed exclusively in an upright position and attached to the wall. Baxi is a world.Famous organization that has been producing professional and reliable gas equipment for a long time.
The boiler Baxi Main Four 240 F has optimal and quite compact dimensions, so it can be installed in any conditions, even in a limited space. Consumers will be able to evaluate the new digital control panel, which is equipped with a wide liquid crystal display and additional buttons for installing optimal modes. Thus, you can check the operation of the boiler easily and quickly. Older people will appreciate clear and simple symbols that, if necessary, will be able to notify a person about a malfunction or failure in the operation of the device.
The boiler Baxi Main Four 240 F is equipped with a forced system for removing combustion products and a closed camera.
How to steal air from a heating system
Surely many people faced such a problem when, touching the heating radiator, they understood that its upper part is hot and the lower one was absolutely cold. This is the first sign that in the heating radiators there is air that does not allow the coolant to enter the lower part of the radiator, thereby heating it.
Therefore, answering the question of what the heating system affects, we can safely say what is influenced, primarily on the efficiency of the entire heating system. With one heated half, the heating radiator will not be able to give as much heat to the premises as with its normal functioning.
Publishing the heating system also affects the performance of the heating boiler. The pump of the heating boiler is much easier to pump the coolant without air in it. Often the reasons for stopping the circulation pump in the heating boiler, there is also an excess of air in the heating system.
These are not all problems associated with the bullying of the heating system, since there are much more of them. Therefore, it is obvious that how, having heard that in the heating radiators, something gurgles, and this is nothing more than air, you should immediately start fainting the heating system.
In fact, the heating system is not very difficult. Depending on what kind of heating radiators are in the house, the heating system will turn out in several ways.
How to drive air out of old cast.Iron batteries
If old cast.Iron heating batteries are installed in the house, then in order to steal air from the heating system, there should be a small ball valve on the upper part of the battery. Having opened the crane, you need to wait until all the air comes off the heating device and one water does not go. If there is no crane, then with the help of plumbing “crabs” you can unscrew the nut or fainter, thereby frightening the air from the cast.Iron battery.
How to expel air from aluminum heating radiators
It is much easier to the situation if you need to steal air from the heating system if new aluminum or steel panel radiators are installed in the house or apartment. In such heating devices, on top of one of the side sides, there must be a crane of Maevsky.
In order to break the radiator using the Maevsky crane, a special Maevsky key is used, which is inserted into the crane, and then turns counterclockwise at several revolutions. After the air has completely left the air from the heating radiator, you can tighten Maevsky’s crane back on the hand.
It happens that a key, Maevsky is not possible to find, then you can use it in order to steal the air from the radiator with an ordinary flat screwdriver. But only a prerequisite in this case. The screwdriver should have a subtle and durable sting.
Otherwise, the screwdriver can simply be tanned. The fact is that in the process of heating the radiator, the maevsky crane can simply “boil” and stick. Therefore, unscrewing it with a screwdriver is often problematic.
As you can see, the bullying of the heating system is not such a big problem as it seems at first glance. Well, in order to steal air from the heating system, it will take no more than half an hour, well, or an hour maximum.
Pressure setting
To raise pressure, a fuel tap is used, and in order to lower the pressure, the descent valve.
The range of 0.7-1 MBAR is considered the best value. Typically, Baxi boilers independently support the right value, but sometimes failures arise. If there is a constant fall that does not disappear after the system is fed, then somewhere there is a leakage.
This may mean either a leak of pipelines or radiators, a warm floor system or other external elements.
Often the problem arises due to a malfunction of the descent valve. An abnormal increase in pressure may be due to a malfunction or open tap of recharge or damage to the membrane of the expansion tank.
How to turn it on
Connecting the boiler to the power supply network is carried out only after the connection of all pipelines supplying water, OV and gas.
Ignition Fault Baxi Solo 30 SE
It is necessary to carefully check the correctness of the connections, pay special attention to the gas pipeline.
Check the absence of leaks using a soap solution, if the deficiencies detect immediately fix them on your own or with the involvement of specialists of the corresponding profile. After that, the boiler can be filled with water, opening the fuel tap.
The pressure should be from 0.7 to 1 MBAR. When the pressure reaches the desired value, you can start the boiler.
Manipulations before installation work
The presented boiler is intended for the highest possible water heating to the optimum temperature of the boiling point at atmospheric pressure. The Baxi Main Four 240 F device must be connected to heating installations and distribution networks of hot household water. Before purchasing, each person must carefully read the instructions, as well as determine the compatibility of all the declared characteristics and power.
BAXI Main Four 240 F Boiler Before connecting you need:
- Wash thoroughly, and clean the pipelines to remove possible impurities;
- Check the suitability of the boiler to work on the supplied gas. This can be done thanks to the inscription on the factory packaging or on the plate, which is attached to the passport;
- Determine the optimal indicators of chimney traction. The boiler should not have narrowing or other graduation pipes from other devices;
- Equip the proper type of chimney so that there are no narrowing and final pipes are connected to other devices;
- The boiler joins at an existing chimney. The owner needs to carefully check its cleanliness, because during the design of the design, slags can be separated from the walls and become an obstacle for the free release of outgoing gas.
Error codes and causes of malfunctions of wall gas boilers Baxi
The consolidated shelter of the malfunctions of the wall.Mounted gas boilers Baxi, equipped with a liquid crystal (LCD) display, models Eco Compact, Four Tech, Eco Four, Main Four, Main 5.
E01 (01E). Flame control sensor. Blocking the boiler after three unsuccessful ignition attempts:
- No gas, a gas valve is closed, low pressure in the gas pipe.
- The phase and zero wires of the power grid for phase.Dependent models of boilers are mixed up.
- Faulty, contaminated ionization electrode of flame control
- Faulty block or ignition electrodes.
- The gas valve is faulty or incorrectly adjusted.
- Air lack for gas burning in a boiler burner
E02 (02E). A temperature sensor of the heating circuit. Overheating of the coolant in the heating circuit:
- Temperature sensor malfunction.
- Insufficient heat transfer to the sensor. At the place of fit of the sensor body to the adjacent part of the boiler, it is recommended to apply thermal pulp.
- Insufficient circulation of the coolant through the heat exchanger due to the malfunction of the pump, the presence of air in the system
E03 (03E). Traction sensor (thermostat in boilers with open or pneumorela in boilers with a closed combustion chamber). Insufficient thrust in the chimney or chimney system:
Only for boilers with an open combustion chamber. As a result of a violation of traction, there was a overheating of the heat rod of the smoke gases and, as a result, the emergency shutdown of the boiler. Check the chimney and the presence of the required traction in it.
Check the smoke pipe for the density of the joints and connectors, for compliance with the recommendations of the manufacturer of the length and diameter, for the absence of obstacles in the smoke channel (clogging, icing), to blow out and back the thrust of the wind (to the location of the head of the smoke pipe relative to the roof)
Check the free flow of air into the room where the boiler is installed. There must be a supply hole from the street or from a neighboring room with windows.
For a boiler with an open combustion chamber, if the air enters directly from the street, then the supply opening of ventilation is enough, at the rate of 8 cm 2 per 1 kW of the boiler power, but not less than 200 cm 2. If the flow of air comes from the neighboring room of the building, then the minimum size of the supply ventilation hole should be determined at the rate of 30 cm 2 per 1 kW of the boiler power. The supply valve in a room with a boiler is installed at a height of not more than 30 cm. From the floor. It can be a ventilator in the wall or in the door, or just a gap under the door.
Note: Electric hoods in a room with a boiler are prohibited.
Check the serviceability of the thermostat of the outgoing gases.
E04 (04E). Flame control sensor. Frequent, more than six times, loss of flame on the burner:
E05 (05E). A temperature sensor of the heating circuit. Lack of signal from the sensor:
E06 (06E). Temperature sensor of the dowry circuit. Lack of signal from the sensor:
E07 (07E). NTC temperature sensor of smoke gases. Lack of signal from the sensor:
E08 (08E). Electronic board. Error in the flame control circuit:
- There is no grounding of an electronic board, there is no contact in the circuit between the board (connector X4) and the power box.
- Electronic control malfunction.
E09 (09E). Electronic board. Error in the gas valve safety circuit:
E10 (10E). The relay of the minimum pressure of the heating circuit. Insufficient pressure pressure in the heating circuit:
E12 (12E). Differential hydraulic pressostat. There is no signal from the press start:
- The circulation pump does not work.
- The heating system has been drew up.
- Insufficient circulation of the coolant (clogged filter, great hydraulic resistance of the heating system).
- A malfunction of the press startup (membrane, microswitch, pulsed tube)
E13 (13E). Differential hydraulic pressostat. False signal from the press.Steaming: flipped contacts of the microwter of the press startup.
E22 (22E). Electronic board. Disconnecting the boiler due to low voltage in the mains, less than 162 in.:
E25 (25E). A temperature sensor of the heating circuit. The temperature growth rate in the heating circuit is more than 1 about s/s.:
Весенний Чегем и полëты на параплане. Spring Chegem and paragliding
- The circulation pump does not work.
- The heating system has been drew up.
- Insufficient circulation of the coolant (clogged filter, great hydraulic resistance of the heating system).
- The temperature sensor of the heating circuit temperature.
E26 (26E). A temperature sensor of the heating circuit. Exceeding the temperature of the coolant is more than 20 ° C from the given:
- The circulation pump does not work.
- The heating system has been drew up.
- Insufficient circulation of the coolant (clogged filter, great hydraulic resistance of the heating system).
- The temperature sensor of the heating circuit temperature.
E27 (27E). Temperature sensor of the dowry circuit. Incorrect position of the sensor:
E32 (32E). Temperature sensors of the DOS and heating circuit. Excess heating temperature above 95 ° C is twice in a row. Decrease in the temperature of the water in the dowry circuit by 3 o.:
E35 (35E). Flame control sensor. Signal about the presence of a flame after disconnecting the burner:
- The gas valve is faulty, does not completely overlap the gas supply.
- Moisture hit the electronic board of the boiler.
- Interference from the electric network. It is necessary to install a voltage stabilizer with a galvanic denouement from the mains, check the serviceability of the boiler grounding.
E36 (36E). Smoke temperature sensor. The NTC sensor of the smoke gases is faulty.
E40 (40E). Smoke temperature sensor. GDC does not pass cyclic tests in the temperature of the smoke gases:
Temperature adjustment
To add or reduce the temperature of the oat and left of the display, there are buttons “” and “-” (there are a special regulator on older models, the temperature rises clockwise and vice versa).
If an indoor thermostat is used, adjustment is made from it, and only the limit values are installed on the boiler.
When setting temperature, the parameters should not be changed with jumps to large sizes. It is necessary to change the regime smoothly, give some time to overcome the inertia of the system. This will mitigate the transition to another mode and extend the life of the boiler.
Baxi boilers
Consider the basic device of the Baxi boiler. The principal scheme is printed in the instruction manual for each specific model, but the main nodes will be the same.
The chimney is located at the top. Immediately under it is installed a fan with a vendori tube and an exhaust cap for the output of combustion products. Below is the primary heat exchanger, having the appearance of a radiator and a coil, a little to the left is a safety thermostat and a NTC heating temperature sensor.
The center is located in the center, inside which there is a burner and electrodes of ignition and ionization of the flame. A gas ramp with nozzles is connected to the modulation burner, which receives gas from a gas valve.
A pipe connected to an expansion tank and circulation pump comes out of the right side from the heat exchanger. The pump is equipped with an automatic air sophistication valve. It ends below the drain of the coolant from the apparatus and by the pressure gauge, water from the heating system of the house enters it.
A pipe is lowered on the left side, on which a hydraulic pressure relay and a safety valve are installed at the end. Water comes out of it into the heating system. These pipes are connected by automatic bypass.
In dual.Circuit models, a secondary plate heat exchanger, priority sensor of the hot water and a three.Stage valve are additionally installed. Series of models of Baxi Moon 3 Combi and Nulova 3 are equipped with an indirect sizes of a small volume.
Main 5 boilers are equipped with a bitmatic heat exchanger, which simultaneously heats both running water and coolant. This is implemented due to the fact that there is another pipe of the smaller diameter that flows from the tube from the heating system, according to which water supply flows.
In front, an electronic control board has been installed. In the electric circuit printed in the operating manual, it is shown to which places all the elements and sensors of the boiler are connected to it. You can figure it out on it how the electric part of the equipment works.
Outside, a steel casing is installed, on which there is an electric control panel with the buttons on and select the mode of operation from below. In modern models, a display is installed for the output of technical data and error codes in case of malfunction.